enow.com Web Search

  1. Ad

    related to: steel beam connection examples

Search results

  1. Results from the WOW.Com Content Network
  2. Structural support - Wikipedia

    en.wikipedia.org/wiki/Structural_support

    It is a rigid type of support or connection. The application of the fixed support is beneficial when we can only use single support, and people most widely used this type as the only support for a cantilever. [7] They are common in beam-to-column connections of moment-resisting steel frames and beam, column and slab connections in concrete frames.

  3. Slip-critical joint - Wikipedia

    en.wikipedia.org/wiki/Slip-critical_joint

    Shear (and tension) loads can be transferred between two structural elements by either a bearing-type connection or a slip-critical connection. In a slip-critical connection, loads are transferred from one element to another through friction forces developed between the faying surfaces of the connection. These friction forces are generated by ...

  4. Structural steel - Wikipedia

    en.wikipedia.org/wiki/Structural_steel

    Structural steel fireproofing materials include intumescent, endothermic and plaster coatings as well as drywall, calcium silicate cladding, and mineral or high temperature insulation wool blankets. Attention is given to connections, as the thermal expansion of structural elements can compromise fire-resistance rated assemblies.

  5. Gusset plate - Wikipedia

    en.wikipedia.org/wiki/Gusset_plate

    The gusset plate is welded to a beam, and then two or three columns, beams, or truss chord are connected to the other side of the gusset plate through bolts or rivets or welds. [3] A uniform force bracing connection connects a beam, column, and one other member. The gusset plate is bolted to the column and welded to the beam.

  6. Pin and hanger assembly - Wikipedia

    en.wikipedia.org/wiki/Pin_and_hanger_assembly

    Attempts have been made to increase the safety of bridges with pin and hanger assemblies by adding some form of redundancy to the assembly. Retrofits that add redundancy to pin and hanger assemblies include adding a "catcher's mitt"‍—‌a short steel beam attached to the bottom of the cantilevered girder that extends out beneath the suspended girder to "catch" the suspended girder should ...

  7. Portal frame - Wikipedia

    en.wikipedia.org/wiki/Portal_frame

    A portal frame steel building under construction. Portal frame is a construction technique where vertical supports are connected to horizontal beams or trusses via fixed joints with designed-in moment-resisting capacity. [1] The result is wide spans and open floors. Portal frame structures can be constructed using a variety of materials and ...

  8. Rigid frame - Wikipedia

    en.wikipedia.org/wiki/Rigid_frame

    The secant stiffness of the connection is compared to the rotational stiffness of the connected member as follows, in which L and EI are the length and bending rigidity, respectively, of the beam. If K s L/EI ≥ 20, it is acceptable to consider the connection to be fully restrained (in other words, able to maintain the angles between members).

  9. I-beam - Wikipedia

    en.wikipedia.org/wiki/I-beam

    The dimension of a wide-flange I-beam. In the United States, steel I-beams are commonly specified using the depth and weight of the beam. For example, a "W10x22" beam is approximately 10 in (254 mm) in depth with a nominal height of the I-beam from the outer face of one flange to the outer face of the other flange, and weighs 22 lb/ft (33 kg/m).

  1. Ad

    related to: steel beam connection examples