  2. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s, e.g. water. [clarify]

  3. Automatic balancing valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_balancing_valve

    In a variable primary chilled-water system, the design flow rate is determined by the water flow velocity in the tube of the coils. At typical conditions, 6–7 feet per second (1.8–2.1 m/s) Maximum 12 ft/s (3.7 m/s) Minimum 1.5 ft/s (0.46 m/s) (based on a Reynolds number of 7500) Minimum flow is typically 50% or less of the design flow. [1]

  4. Flow distribution in manifolds - Wikipedia

    en.wikipedia.org/wiki/Flow_distribution_in_manifolds

    Thus the velocities should be equal in two outlets or the flow rates should be equal according to the assumptions. Obviously this disobeys our observations. Our observations show that the greater the velocity (or momentum), the more fluid fraction through the straight direction. Only under very slow laminar flow, Q 2 may be equal to Q 3. Fig. 3.

  5. Hydronic balancing - Wikipedia

    en.wikipedia.org/wiki/Hydronic_balancing

    Hydronic balancing, also called hydraulic balancing, is the process of optimizing the distribution of water in a building's hydronic heating or cooling system by equalizing the system pressure. In a balanced system every radiator is set to receive the proper amount of fluid in order to provide the intended indoor climate at optimum energy ...

  6. Hazen–Williams equation - Wikipedia

    en.wikipedia.org/wiki/Hazen–Williams_equation

    The Hazen–Williams equation is an empirical relationship that relates the flow of water in a pipe with the physical properties of the pipe and the pressure drop caused by friction. It is used in the design of water pipe systems [1] such as fire sprinkler systems, [2] water supply networks, and irrigation systems.

  7. Dynamic pressure - Wikipedia

    en.wikipedia.org/wiki/Dynamic_pressure

    In fluid dynamics, dynamic pressure (denoted by q or Q and sometimes called velocity pressure) is the quantity defined by: [1] = where (in SI units): q is the dynamic pressure in pascals (i.e., N/m 2, ρ (Greek letter rho) is the fluid mass density (e.g. in kg/m 3), and; u is the flow speed in m/s.

  8. Darcy–Weisbach equation - Wikipedia

    en.wikipedia.org/wiki/Darcy–Weisbach_equation

    Even in the case of laminar flow, where all the flow lines are parallel to the length of the pipe, the velocity of the fluid on the inner surface of the pipe is zero due to viscosity, and the velocity in the center of the pipe must therefore be larger than the average velocity obtained by dividing the volumetric flow rate by the wet area.

  9. Flow measurement - Wikipedia

    en.wikipedia.org/wiki/Flow_measurement

    Velocity times the cross-sectional area yields a flow rate which can be integrated into volumetric flow. There are two types of area velocity flowmeter: (1) wetted; and (2) non-contact. Wetted area velocity sensors have to be typically mounted on the bottom of a channel or river and use Doppler to measure the velocity of the entrained particles.