Search results
Results from the WOW.Com Content Network
Diagram of a RAID 1 setup. RAID 1 consists of an exact copy (or mirror) of a set of data on two or more disks; a classic RAID 1 mirrored pair contains two disks.This configuration offers no parity, striping, or spanning of disk space across multiple disks, since the data is mirrored on all disks belonging to the array, and the array can only be as big as the smallest member disk.
As a RAID 0 array striped across RAID 5 elements, minimal RAID 50 configuration requires six drives. On the right is an example where three collections of 120 GB RAID 5s are striped together to make 720 GB of total storage space. One drive from each of the RAID 5 sets could fail without loss of data; for example, a RAID 50 configuration ...
RAID (/ r eɪ d /; redundant array of inexpensive disks or redundant array of independent disks) [1] [2] is a data storage virtualization technology that combines multiple physical data storage components into one or more logical units for the purposes of data redundancy, performance improvement, or both.
RAID stands for redundant array of independent disks (or, formerly, redundant array of inexpensive disks). RAID levels may refer to: Standard RAID levels, all the RAID configurations defined in the Common RAID Disk Drive Format standard, which is maintained by the Storage Networking Industry Association
RAID 5E, RAID 5EE, and RAID 6E (with the added E standing for Enhanced) generally refer to variants of RAID 5 or 6 with an integrated hot-spare drive, where the spare drive is an active part of the block rotation scheme. This spreads I/O across all drives, including the spare, thus reducing the load on each drive, increasing performance.
RAID In some RAID configurations, such as RAID 0, failure of a single member drive of the RAID array causes all stored data to be lost. In other RAID configurations, such as a RAID 5 that contains distributed parity and provides redundancy, if one member drive fails the data can be restored using the other drives in the array. LVM2
bioctl softraid [5] Yes No Yes Yes Yes Yes bioctl on OpenBSD can be used for maintenance of hardware RAID, as well as for both initialisation and maintenance of software RAID Sistina: Linux 2.2 Logical Volume Manager version 1: Yes Yes Yes Yes No No IBM: Linux 2.4 Enterprise Volume Management System: Yes Yes Yes Yes Yes No Sistina: Linux 2.6 ...
It often implements hardware RAID, thus it is sometimes referred to as RAID controller. It also often provides additional disk cache . Disk array controller is often ambiguously shortened to disk controller which can also refer to the circuitry responsible for managing internal disk drive operations.