enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    Circuit diagram for open-circuit test. The open-circuit test, or no-load test, is one of the methods used in electrical engineering to determine the no-load impedance in the excitation branch of a transformer. The no load is represented by the open circuit, which is represented on the right side of the figure as the "hole" or incomplete part of ...

  3. Open-circuit time constant method - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_time_constant...

    Select capacitor C 1, replace it by a test voltage V X, and replace C 2 by an open circuit. Then the resistance seen by the test voltage is found using the circuit in the right panel of Figure 1 and is simply V X / I X = R 1. Form the product C 1 R 1. Add these terms. In effect, it is as though each capacitor charges and discharges through the ...

  4. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.

  5. Impedance parameters - Wikipedia

    en.wikipedia.org/wiki/Impedance_parameters

    The equivalent circuit for Z-parameters of a two-port network. The equivalent circuit for Z-parameters of a reciprocal two-port network. The Z-parameter matrix for the two-port network is probably the most common. In this case the relationship between the port currents, port voltages and the Z-parameter matrix is given by:

  6. Glossary of electrical and electronics engineering - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_electrical_and...

    A short circuit, open circuit, or other disruption of a power system. fax Facsimile, the transmission of paper images by radio or by wire. feed forward A control system that adjusts the controlled variable based on a model of the process and measurements of disturbances, instead of feedback from measurement of the process. feedback amplifier

  7. Load regulation - Wikipedia

    en.wikipedia.org/wiki/Load_regulation

    The maximum load is the one that draws the greatest current, i.e. the lowest specified load resistance (never short circuit); is the voltage at minimum load. The minimum load is the one that draws the least current, i.e. the highest specified load resistance (possibly open circuit for some types of linear supplies, usually limited by pass ...

  8. Blocked rotor test - Wikipedia

    en.wikipedia.org/wiki/Blocked_rotor_test

    It is also known as short-circuit test (because it is the mechanical analogy of a transformer short-circuit test), [1] locked rotor test or stalled torque test. [2] From this test, short-circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found.

  9. Smith chart - Wikipedia

    en.wikipedia.org/wiki/Smith_chart

    If the termination is perfectly matched, the reflection coefficient will be zero, represented effectively by a circle of zero radius or in fact a point at the centre of the Smith chart. If the termination was a perfect open circuit or short circuit the magnitude of the reflection coefficient would be unity, all power would be reflected and the ...