Search results
Results from the WOW.Com Content Network
It is used in conditions where the surface soil's load-bearing capacity is less than the anticipated design loads. A grade beam differs from a wall footing because a grade beam is designed for bending and typically spans between pile caps or caissons, while a wall footing bears on soil and transmits the weight of the wall directly into the ground.
Schematic cross section of a pressurized caisson. In geotechnical engineering, a caisson (/ ˈ k eɪ s ən,-s ɒ n /; borrowed from French caisson 'box', from Italian cassone 'large box', an augmentative of cassa) is a watertight retaining structure [1] used, for example, to work on the foundations of a bridge pier, for the construction of a concrete dam, [2] or for the repair of ships.
Since then, suction caissons have been installed at even larger depths, but the Diana installation was a technology breakthrough for the 20th century. [6] An important development step for the suction caisson technology emerged from cooperation between the former operator in the North Sea, Saga Petroleum AS, and Norwegian Geotechnical Institute ...
Also called caissons, drilled shafts, drilled piers, cast-in-drilled-hole piles (CIDH piles) or cast-in-situ piles, a borehole is drilled into the ground, then concrete (and often some sort of reinforcing) is placed into the borehole to form the pile. Rotary boring techniques allow larger diameter piles than any other piling method and permit ...
Static load testing is an in situ type of load testing used in geotechnical investigation to determine the bearing capacity of deep foundations prior to the construction of a building. It differs from the statnamic load test and dynamic load testing in that the pressure applied to the pile is slower.
The pile shaft transfers a structure's load into the pile. Helical steel plates are welded to the pile shaft to suit the site specific ground conditions. Helices can be press-formed to a specified pitch or simply consist of flat plates welded at a specified pitch to the pile's shaft.
In geotechnical engineering, a tieback is a structural element installed in soil or rock to transfer applied tensile load into the ground. Typically in the form of a horizontal wire or rod, or a helical anchor, a tieback is commonly used along with other retaining systems (e.g. soldier piles , sheet piles, secant and tangent walls) to provide ...
Dynamic load testing (or dynamic loading) is a method to assess a pile's bearing capacity by applying a dynamic load to the pile head (a falling mass) while recording acceleration and strain on the pile head. Dynamic load testing is a high strain dynamic test which can be applied after pile installation for concrete piles. For steel or timber ...