By far the most common devices used in industry have a nominal resistance of 100 ohms at 0 °C and are called Pt100 sensors ("Pt" is the symbol for platinum, "100" for the resistance in ohms at 0 °C). It is also possible to get Pt1000 sensors, where 1000 is for the resistance in ohms at 0 °C.
A chemical sensor array is a sensor architecture with multiple sensor components that create a pattern for analyte detection from the additive responses of individual sensor components. There exist several types of chemical sensor arrays including electronic, optical, acoustic wave, and potentiometric devices.
Potentiometric solid state gas sensors have been generally classified into three broad groups. Type I sensors have an electrolyte containing mobile ions of the chemical species in the gas phase that it is monitoring. The commercial product, YSZ oxygen sensor, [1] is an example of type I.
A potentiostat is a control and measuring device. It comprises an electric circuit which controls the potential across the cell by sensing changes in its resistance, varying accordingly the current supplied to the system: a higher resistance will result in a decreased current, while a lower resistance will result in an increased current, in order to keep the voltage constant as described by ...
Instrumentation and control engineering is a vital field of study offered at many universities worldwide at both the graduate and postgraduate levels. This discipline integrates principles from various branches of engineering, providing a comprehensive understanding of the design, analysis, and management of automated systems.
A ChemFET is a chemically-sensitive field-effect transistor, that is a field-effect transistor used as a sensor for measuring chemical concentrations in solution. [1] When the target analyte concentration changes, the current through the transistor will change accordingly. [2] Here, the analyte solution separates the source and gate electrodes. [3]
Potentiometry passively measures the potential of a solution between two electrodes, affecting the solution very little in the process. One electrode is called the reference electrode and has a constant potential, while the other one is an indicator electrode whose potential changes with the sample's composition.
The method was described by Johann Christian Poggendorff around 1841 and became a standard laboratory measuring technique. [1] In this arrangement, a fraction of a known voltage from a resistive slide wire is compared with an unknown voltage by means of a galvanometer. The sliding contact or wiper of the potentiometer is adjusted and the ...