From NFPA 72, 2002 Edition: “7.4.2.1* To ensure that audible public mode signals are clearly heard, unless otherwise permitted by 7.4.2.2 through 7.4.2.5, they shall have a sound level at least 15 dB above the average ambient sound level or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater ...
The standard details requirements for a range of alarm systems including central station burglar alarms, police station connected alarms, local alarms, proprietary systems, holdup alarms, and digital alarm communicator system units. It also covers power supplies essential for burglar-alarm equipment operation.
Although photoelectric alarms are highly effective at detecting smoldering fires and do provide adequate protection from flaming fires, fire safety experts and the NFPA recommend installing what are called combination alarms, which are alarms that either detect both heat and smoke or use both the ionization and photoelectric smoke sensing methods.
The NFPA 72 "covers the application, installation, location, performance, inspection, testing, and maintenance of fire alarm systems, supervising station alarm systems, public emergency alarm reporting systems, fire warning equipment and emergency communications systems (ECS), and their components."
New codes and standards introduced around 2010, especially the new UL Standard 2572, the US Department of Defense's UFC 4-021-01 Design and O&M Mass Notification Systems, and NFPA 72 2010 edition Chapter 24, have led fire alarm system manufacturers to expand their systems voice evacuation capabilities to support new requirements for mass ...
A report by the UK-based Building Research Establishment (BRE) stated "there is a commonly held view that equipment designed to meet the European EN54 Fire detection and fire alarm systems standard cannot be used within an installation designed to the US National Fire Alarm Code, NFPA 72." In actuality, "there appears to be no requirement in ...
In the United States, the National Fire Protection Association sets standards for PASS devices in NFPA 1982. [ 1 ] The PASS device is normally used in conjunction with breathing apparatus; it is a small, battery-powered device attached to the self-contained breathing apparatus (SCBA) harness which enables the firefighter to summon help by ...
The National Fire Protection Association (NFPA) is a U.S.-based international nonprofit organization devoted to eliminating death, injury, property, and economic loss due to fire, electrical, and related hazards.