A fault current limiter (FCL), also known as fault current controller (FCC), [1] is a device which limits the prospective fault current when a fault occurs (e.g. in a power transmission network) without complete disconnection.
Early applications will be where the benefit of smaller size, lower weight or the ability to rapidly switch current (fault current limiters) outweighs the added cost. Longer-term as conductor price falls HTS systems should be competitive in a much wider range of applications on energy efficiency grounds alone.
An inrush current limiter is a device or devices combination used to limit inrush current. Passive resistive components such as resistors (with power dissipation drawback), or negative temperature coefficient (NTC) thermistors are simple options while the positive one (PTC) is used to limit max current afterward as the circuit has been operating (with cool-down time drawback on both).
Due to the fast recharge times and fast alternating current to direct current conversion process of SMES systems, these systems can be used as a spinning reserve when a major grid of transmission line is out of service. [18] [19] SFCL. Superconducting fault current limiters (SFCL) are used to limit current under a fault in the grid.
Current limiting reactors, once called current limiting reactance coils, were first presented in 1915. [2] The inventor of the current limiting reactance coil was Vern E. Alden who filed the patent on November 20, 1917 with an issue date of September 11, 1923. The original assignee was Westinghouse Electric & Manufacturing Company. [3]
An inrush current limiter is a component used to limit inrush current to avoid gradual damage to components and avoid blowing fuses or tripping circuit breakers.
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or current flowing to another powered conductor.
Low-resistance grounding systems use a neutral grounding resistor (NGR) to limit the fault current to 25 A or greater. Low resistance grounding systems will have a time rating (say, 10 seconds) that indicates how long the resistor can carry the fault current before overheating. A ground fault protection relay must trip the breaker to protect ...