Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.
Displacement ventilation is best suited for taller spaces (higher than 3 meters [10 feet]). [2] Standard mixing ventilation may be better suited for smaller spaces where air quality is not as great a concern, such as single-occupant offices, and where the room height is not tall (e.g., lower than 2.3 meters [7.5 feet]).
Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor ...
A sewer pipe is normally at neutral air pressure compared to the surrounding atmosphere.When a column of waste water flows through a pipe, it compresses air ahead of it in the system, creating a positive pressure that must be released so it does not push back on the waste stream and downstream traps, slow drainage, and induce potential clogs.
The hourly ventilation rate divided by the volume of a space. For perfectly mixed air or laminar flow spaces, this is equal to the number of times per hour that the volume the space is exchanged by mechanical and natural ventilation. Also called air change rate or air exchange rate. Abbreviated ACH or ac/hr. air conditioner
Floor drain system in bathroom, Korea. A floor drain is a plumbing fixture that is installed in the floor of a structure, mainly designed to remove any standing water near it. They are usually round, but can also be square or rectangular. They usually range from 2 to 12 inches (5.1 to 30.5 cm); most are 4 inches (10 cm) in diameter.
In plumbing, a Fixture Unit (FU) or Drain Fixture Unit (DFU) is "a unit of measure, based on the rate of discharge, time of operation and frequency of use of a fixture, that expresses the hydraulic load imposed by that fixture on the sanitary plumbing installation". [1] A Fixture Unit is not a flow rate unit but a design factor.
A floor register. A register is a grille with moving parts, capable of being opened and closed and the air flow directed, which is part of a building's heating, ventilation, and air conditioning (HVAC) system. The placement and size of registers is critical to HVAC efficiency. Register dampers are also important, and can serve a safety function.