enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Voltage control and reactive power management - Wikipedia

    en.wikipedia.org/wiki/Voltage_control_and...

    injection of reactive power into transmission lines causes losses that waste power, forcing an increase in power supplied by the prime mover. Use of specialized voltage control devices in the grid also improves the power system stability by reducing the fluctuations of the rotor angle of a synchronous generator (that are caused by generators ...

  3. Active Network Management - Wikipedia

    en.wikipedia.org/wiki/Active_Network_Management

    In electricity distribution circuits, Active Network Management (ANM) describes control systems that manage generation and load for specific purposes. This is usually done to keep system parameters (voltage, power, phase balance, reactive power and frequency) within predetermined limits. ANM generally refers to automated systems.

  4. Unified power flow controller - Wikipedia

    en.wikipedia.org/wiki/Unified_Power_Flow_Controller

    A unified power flow controller (UPFC) is an electrical device for providing fast-acting reactive power compensation on high-voltage electricity transmission networks. It uses a pair of three-phase controllable bridges to produce current that is injected into a transmission line using a series transformer. [ 1 ]

  5. HVDC converter station - Wikipedia

    en.wikipedia.org/wiki/HVDC_converter_station

    When line commutated converters are used, the converter station will require between 40% and 60% of its power rating as reactive power. This can be provided by banks of switched capacitors or by synchronous condensers, or if a suitable power generating station is located close to the static inverter plant, the generators in the power station ...

  6. Flexible AC transmission system - Wikipedia

    en.wikipedia.org/wiki/Flexible_AC_transmission...

    Heavily loaded lines consumed reactive power due to the line's inductance, and as transmission voltage increased throughout the 20th century, the higher voltage supplied capacitive reactive power. As operating a transmission line only at it surge impedance loading (SIL) was not feasible, [2] other means to manage the reactive power was needed.

  7. Voltage regulation - Wikipedia

    en.wikipedia.org/wiki/Voltage_regulation

    Three power factor scenarios are shown, where (a) the line serves an inductive load so the current lags receiving end voltage, (b) the line serves a completely real load so the current and receiving end voltage are in phase, and (c) the line serves a capacitive load so the current leads receiving end voltage.

  8. Static VAR compensator - Wikipedia

    en.wikipedia.org/wiki/Static_VAR_compensator

    In Electrical Engineering, a static VAR compensator (SVC) is a set of electrical devices for providing fast-acting reactive power on high-voltage electricity transmission networks. [1] [2] SVCs are part of the flexible AC transmission system [3] [4] device family, regulating voltage, power factor, harmonics and stabilizing the system. A static ...

  9. Slack bus - Wikipedia

    en.wikipedia.org/wiki/Slack_bus

    The real power and voltage are specified for buses that are generators. These buses have a constant power generation, controlled through a prime mover, and a constant bus voltage. Slack bus – to balance the active and reactive power in the system. It is also known as the Reference Bus or the Swing Bus. The slack bus will serve as an angular ...