Search results
Results from the WOW.Com Content Network
Juno; Lightolier; Typical systems have line voltage running through a recessed track. The track may have more than one live conductor, so that multiple switched circuits can be used to control different fittings on the same track. Installers will place the tab of the connector on the fixture to one side or the other when attaching it to the track.
An inrush current limiter is a device or devices combination used to limit inrush current. Passive resistive components such as resistors (with power dissipation drawback), or negative temperature coefficient (NTC) thermistors are simple options while the positive one (PTC) is used to limit max current afterward as the circuit has been operating (with cool-down time drawback on both).
A typical application of inrush current limiters is in the input stage of non-power factor corrected switching supplies, to reduce the initial surge of current from the line input to the reservoir capacitor. The most popular application is the inrush protection of the AC current in switching power supplies (SPS).
A fault current limiter (FCL), also known as fault current controller (FCC), [1] is a device which limits the prospective fault current when a fault occurs (e.g. in a power transmission network) without complete disconnection. The term includes superconducting, solid-state and inductive devices. [2]
Limiting can refer to a range of treatments designed to limit the maximum level of a signal. Treatments in order of decreasing severity range from clipping, in which a signal is passed through normally but sheared off when it would normally exceed a certain threshold; soft clipping which squashes peaks instead of shearing them; a hard limiter, a type of variable-gain audio level compression ...
The controller reduces the returned volts to the light. If the controller returns the full 10 V, the light will be at its brightest level. The light will be at minimum level if no volts are returned. The current sinking scheme creates a fail safe situation. Should a control wire be cut or the controller fail, the lights will illuminate ...
A lighting control system is intelligent network-based lighting control that incorporates communication between various system inputs and outputs related to lighting control with the use of one or more central computing devices. Lighting control systems are widely used on both indoor and outdoor lighting of commercial, industrial, and ...
It is known as a current-limiting diode (CLD) or current-regulating diode (CRD). Internal structure. It consists of an n-channel JFET with the gate shorted to the source, which functions like a two-terminal current limiter (analogous to a voltage-limiting Zener diode). It allows a current through it to rise to a certain value, but not higher.