Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the spread of smoke inside the ducts. When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at temperatures higher than ambient but low enough to indicate the presence of a fire, allowing springs to ...
AMCA Publication 502 - Damper Application Manual for Heating, Ventilating, and Air Conditioning is a guide to understanding the various types of dampers available and items to be considered for their proper use. Dampers classified as fire dampers, heat dampers, and smoke dampers are not included.
Smoke damper may be used to prevent the spread of smoke from the space of fire origin to other spaces in the same building. A combination of fans and dampers can exhaust smoke from an area while pressurizing the smoke-free areas around the affected area (inhibiting smoke infiltration into additional areas).
Vertically mounted fire dampers are gravity operated, while horizontal fire dampers are spring powered. A fire damper's most important feature is a mechanical fusible link which is a piece of metal that will melt or break at a specified temperature. This allows the damper to close (either from gravity or spring power), effectively sealing the ...
A damper or adjustable louver designed to augment the ventilation of a space during a fire. split system A split system is the combination of an outdoor unit and an indoor unit. This is the most common type of system. superheat The number of degrees a vapor is above its boiling point at a specific pressure. subcooling
Mechanical fusible links are utilized as the triggering device in fire sprinkler systems and mechanical automatic door release mechanisms that close fire doors in warehouses, etc. Fire dampers in ventilation systems have fusible links so that the dampers close automatically in case of fire, limiting the spread of flame or hot gases through a ...
The majority of guidance available for design of heat and smoke building vents installed in buildings is restricted to nonsprinklered, single-story buildings. [4] This is partly a historical consequence of the installation of heat and smoke vents following the August 1953 General Motors, Livonia, MI major fire in a nonsprinklered manufacturing facility which effectively stopped the production ...
These intumescent materials produce a light char which is a poor conductor of heat, thus retarding heat transfer.Typically the light char consists of microporous carbonaceous foam formed by a chemical reaction of three main components: ammonium polyphosphate, pentaerythritol, and melamine. [2]