enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Power system protection is a branch of electrical power engineering that deals with the protection of electrical power systems from faults [citation needed] through the disconnection of faulted parts from the rest of the electrical network. The objective of a protection scheme is to keep the power system stable by isolating only the components ...

  3. Overcurrent - Wikipedia

    en.wikipedia.org/wiki/Overcurrent

    Possible causes for overcurrent include short circuits, excessive load, incorrect design, an arc fault, or a ground fault. Fuses, circuit breakers, and current limiters are commonly used overcurrent protection (OCP) mechanisms to control the risks. Circuit breakers, relays, and fuses protect circuit wiring from damage caused by overcurrent. [1]

  4. Current limiting - Wikipedia

    en.wikipedia.org/wiki/Current_limiting

    According to the 2020 NEC/NFPA 70, a current-limiting overcurrent protective device is defined as, "A device that, when interrupting currents in its current-limiting range, reduces the current flowing in the faulted circuit to a magnitude substantially less than that obtainable in the same circuit if the device were replaced with a solid ...

  5. Protective relay - Wikipedia

    en.wikipedia.org/wiki/Protective_relay

    An overcurrent relay is a type of protective relay which operates when the load current exceeds a pickup value. It is of two types: instantaneous over current (IOC) relay and definite time overcurrent (DTOC) relay. The ANSI device number is 50 for an IOC relay or a DTOC relay. In a typical application, the over current relay is connected to a ...

  6. ANSI device numbers - Wikipedia

    en.wikipedia.org/wiki/ANSI_device_numbers

    Device numbers may be combined if the device provides multiple functions, such as the Instantaneous / Time-delay Overcurrent relay denoted as 50/51. [ 3 ] For device 16, the suffix letters further define the device: the first suffix letter is 'S' for serial or 'E' for Ethernet.

  7. Circuit breaker (overcurrent) - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker_(overcurrent)

    Breakers for protections against earth faults too small to trip an over-current device: Residual-current device (RCD), or residual-current circuit breaker (RCCB) — detects current imbalance, but does not provide over-current protection. In the United States and Canada, these are called ground fault circuit interrupters (GFCI).

  8. Mortgage protection insurance: What it is and when you might ...

    www.aol.com/finance/mortgage-protection...

    Mortgage protection insurance is an insurance policy that pays off the remainder of your mortgage if you pass away or if you become disabled and can’t work. In that way, it functions similarly ...

  9. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    The time domain reflectometer sends a pulse down the wire and then analyzes the returning reflected pulse to identify faults within the electrical wire. In historic submarine telegraph cables , sensitive galvanometers were used to measure fault currents; by testing at both ends of a faulted cable, the fault location could be isolated to within ...