enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Ambient noise level - Wikipedia

    en.wikipedia.org/wiki/Ambient_noise_level

    A pascal is a newton per square meter. The centimeter-gram-second system of units, the reference sound pressure for measuring ambient noise level is 0.0002 dyn/cm 2, or 0.00002 N/m 2. [6] Most frequently ambient noise levels are measured using a frequency weighting filter, the most common being the A-weighting scale, such that resulting ...

  3. Noise curve - Wikipedia

    en.wikipedia.org/wiki/Noise_curve

    In other cases, special noise may also be tolerated or even introduced at higher levels, for example to create acoustic "privacy", or to help mask other more irritating noise sources. The process of determining the single value for a particular room is first to measure the sound frequency spectrum created by the background noise in the room ...

  4. Noise measurement - Wikipedia

    en.wikipedia.org/wiki/Noise_measurement

    Noise may be measured using a sound level meter at the source of the noise. [23] [24] [25] Alternatively, an organization or company may measure a person's exposure to environmental noise in a workplace via a noise dosimeter. [26] The measurements taken using either of these methods will be evaluated according to the standards below.

  5. Sound level meter - Wikipedia

    en.wikipedia.org/wiki/Sound_level_meter

    A noise dosimeter (American) or noise dosemeter (British) is a specialized sound level meter intended specifically to measure the noise exposure of a person integrated over a period of time; usually to comply with Health and Safety regulations such as the Occupational Safety and Health (OSHA) 29 CFR 1910.95 Occupational Noise Exposure Standard ...

  6. Sound reduction index - Wikipedia

    en.wikipedia.org/wiki/Sound_Reduction_Index

    The Sound Reduction Index is expressed in decibels (dB). It is the weighted sound reduction index for a partition or single component only. This is a laboratory-only measurement, which uses knowledge of the relative sizes of the rooms in the test suite, and the reverberation time in the receiving room, and the known level of noise which can pass between the rooms in the suite by other routes ...

  7. A-weighting - Wikipedia

    en.wikipedia.org/wiki/A-weighting

    A graph of the A-, B-, C- and D-weightings across the frequency range 10 Hz – 20 kHz Video illustrating A-weighting by analyzing a sine sweep (contains audio). A-weighting is a form of frequency weighting and the most commonly used of a family of curves defined in the International standard IEC 61672:2003 and various national standards relating to the measurement of sound pressure level. [1]

  8. Signal-to-noise ratio - Wikipedia

    en.wikipedia.org/wiki/Signal-to-noise_ratio

    Signal-to-noise ratio (SNR or S/N) is a measure used in science and engineering that compares the level of a desired signal to the level of background noise. SNR is defined as the ratio of signal power to noise power, often expressed in decibels. A ratio higher than 1:1 (greater than 0 dB) indicates more signal than noise.

  9. Sound transmission class - Wikipedia

    en.wikipedia.org/wiki/Sound_transmission_class

    A higher number indicates more effective sound insulation than a lower number. The STC is a standardized rating provided by ASTM E413 based on laboratory measurements performed in accordance with ASRM E90. ASTM E413 can also be used to determine similar ratings from field measurements performed in accordance with ASTM E336. [3]