enow.com Web Search

  1. Ads

    related to: gauge calibration

Search results

  1. Results from the WOW.Com Content Network
  2. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    This is called a limited calibration. But if the final measurement requires 10% accuracy, then the 3% gauge never can be better than 3.3:1. Then perhaps adjusting the calibration tolerance for the gauge would be a better solution. If the calibration is performed at 100 units, the 1% standard would actually be anywhere between 99 and 101 units.

  3. Gauge (instrument) - Wikipedia

    en.wikipedia.org/wiki/Gauge_(instrument)

    Dial indicator, also known as a dial test indicator, dial gauge, or probe indicator an instrument used to accurately measure small linear distances. Feeler gauge: a simple tool used to measure gap widths. Gauge block, (also known as a gage block, Johansson gauge, slip gauge, or Jo block) a precision ground and lapped length measuring standard.

  4. Gauge block - Wikipedia

    en.wikipedia.org/wiki/Gauge_block

    Gauge blocks (also known as gage blocks, Johansson gauges, slip gauges, or Jo blocks) are a system for producing precision lengths. The individual gauge block is a metal or ceramic block that has been precision ground and lapped to a specific thickness. Gauge blocks come in sets of blocks with a range of standard lengths.

  5. Measurement system analysis - Wikipedia

    en.wikipedia.org/wiki/Measurement_system_analysis

    Common tools and techniques of measurement system analysis include: calibration studies, fixed effect ANOVA, components of variance, attribute gage study, gage R&R, [1] ANOVA gage R&R, and destructive testing analysis. The tool selected is usually determined by characteristics of the measurement system itself.

  6. Hegman gauge - Wikipedia

    en.wikipedia.org/wiki/Hegman_gauge

    A Hegman gauge, sometimes referred to as a grind gauge, grind gage, or grindometer, is an instrument which indicates the fineness of grind or the presence of coarse particles and agglomeration in a dispersion. [1]

  7. Load cell - Wikipedia

    en.wikipedia.org/wiki/Load_cell

    Calibration is conducted incrementally starting working in ascending or descending order. For example, in the case of a 60 tonne load cell, then specific test weights that measure in 5, 10, 20, 40 and 60 tonne increments may be used; a five step calibration process is usually sufficient for ensuring a device is accurately calibrated.

  1. Ads

    related to: gauge calibration