Search results
Results from the WOW.Com Content Network
In aqueous solution, ammonia deprotonates a small fraction of the water to give ammonium and hydroxide according to the following equilibrium: . NH 3 + H 2 O ⇌ NH + 4 + OH −.. In a 1 M ammonia solution, about 0.42% of the ammonia is converted to ammonium, equivalent to pH = 11.63 because [NH +
[88] [89] The raw energy density of liquid ammonia is 11.5 MJ/L, [88] which is about a third that of diesel. Ammonia can be converted back to hydrogen to be used to power hydrogen fuel cells, or it may be used directly within high-temperature solid oxide direct ammonia fuel cells to provide efficient power sources that do not emit greenhouse gases.
Heating at higher temperatures results in decomposition into ammonia, nitrogen, sulfur dioxide, and water. [17] As a salt of a strong acid (H 2 SO 4) and weak base (NH 3), its solution is acidic; the pH of 0.1 M solution is 5.5. In aqueous solution the reactions are those of NH + 4 and SO 2−
For instance, a 5×10 −8 M solution of HCl would be expected to have a pH of 7.3 based on the above procedure, which is incorrect as it is acidic and should have a pH of less than 7. In such cases, the system can be treated as a mixture of the acid or base and water, which is an amphoteric substance.
A liquid fat sample combined with neutralized 95% ethanol is titrated with standardized sodium hydroxide of 0.1 eq/L normality to a phenolphthalein endpoint. The volume and normality of the sodium hydroxide are used, along with the weight of the sample, to calculate the free fatty acid value. [3]
Buffer capacity falls to 33% of the maximum value at pH = pK a ± 1, to 10% at pH = pK a ± 1.5 and to 1% at pH = pK a ± 2. For this reason the most useful range is approximately p K a ± 1. When choosing a buffer for use at a specific pH, it should have a p K a value as close as possible to that pH.
The most common method of eliminating the liquid junction potential is to place a salt bridge consisting of a saturated solution of potassium chloride (KCl) and ammonium nitrate (NH 4 NO 3) with lithium acetate (CH 3 COOLi) between the two solutions constituting the junction. When such a bridge is used, the ions in the bridge are present in ...
The Henderson–Hasselbalch equation can be used to model these equilibria. It is important to maintain this pH of 7.4 to ensure enzymes are able to work optimally. [10] Life threatening Acidosis (a low blood pH resulting in nausea, headaches, and even coma, and convulsions) is due to a lack of functioning of enzymes at a low pH. [10]