Search results
Results from the WOW.Com Content Network
The thermodynamic method is used for performance testing of pumps, flow meter calibration, system curve tests, and other applications. It is capable of achieving results with uncertainties of less than 1% in pump efficiency and less than 1.5% in flow [ 3 ] while being able to test piping configurations where other conventional pump testing ...
Sonar flowmeters have the capacity of measuring the velocity of liquids or gases non-intrusively within the pipe and then leverage this velocity measurement into a flow rate by using the cross-sectional area of the pipe and the line pressure and temperature. The principle behind this flow measurement is the use of underwater acoustics.
It was awarded the Flow Control Innovations Award in 2011. [2] Sage Metering was the first thermal flow meter manufacturer to provide a unique and easy to invoke on-site calibration verification. [3] (This saves time and money since the user does not have to remove the meter and return it to the factory (or a third party) for annual flow meter ...
A velocity-type meter measures the velocity of flow through a meter of known internal capacity. The speed of the flow can then be converted into a volume of flow to determine the usage. There are several types of meters that measure water flow velocity, including jet meters (single-jet and multi-jet), turbine meters, propeller meters and mag ...
A mass flow controller is designed and calibrated to control a specific type of liquid or gas at a particular range of flow rates. The MFC can be given a setpoint from 0 to 100% of its full scale range but is typically operated in the 10 to 90% of full scale where the best accuracy is achieved.
Measurement and interpretation of 2 and 3 phase multiphase flow can also be achieved by using alternative flow measurement technologies such as SONAR.SONAR meters apply the principles of underwater acoustics to measure flow regimes and; can be clamped on to wellheads and flow lines to measure the bulk (mean) fluid velocity of the total mixture which is then post-processed and analyzed along ...
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
Mechanical current meters are mostly based on counting the rotations of a propeller and are thus rotor current meters. A mid-20th-century realization is the Ekman current meter which drops balls into a container to count the number of rotations.