Substation integration refers to combining data from the IED's local to a substation so that there is a single point of contact in the substation for all of the I&C data. Power-system automation processes rely on data acquisition; power-system supervision and power-system control all working together in a coordinated automatic fashion.
A remote terminal unit (RTU) is a microprocessor-controlled electronic device that interfaces objects in the physical world to a distributed control system or SCADA (supervisory control and data acquisition) system by transmitting telemetry data to a master system, and by using messages from the master supervisory system to control connected objects. [1]
In smaller SCADA systems, the supervisory computer may be composed of a single PC, in which case the HMI is a part of this computer. In larger SCADA systems, the master station may include several HMIs hosted on client computers, multiple servers for data acquisition, distributed software applications, and disaster recovery sites.
Most IEDs have a communication port and built-in support for standard communication protocols (DNP3, IEC104 or IEC61850), so they can communicate directly with the SCADA system or a substation programmable logic controller. Alternatively, they can be connected to a substation RTU that acts as a gateway towards the SCADA server. [2]
The gateway processor approach is similar to the networked server except it is intended for legacy systems with minimal communications networking capability and so has the lowest performance. In the most minimal situation the ICCP gateway may communicate with the SCADA host via a serial port in a similar manner to the SCADA RTUs.
IEC 61850 is an international standard defining communication protocols for intelligent electronic devices at electrical substations.It is a part of the International Electrotechnical Commission's (IEC) Technical Committee 57 reference architecture for electric power systems. [1]
The system under test may be composed of electromechanical or computer hardware, or software, or hardware with embedded software, or hardware/software with human-in-the-loop testing. SIT is typically performed on a larger integrated system of components and subassemblies that have previously undergone subsystem testing.
Automatic Systems International, Inc. (ASI), or Open Systems International (OSI) is an automation software company headquartered in Medina, Minnesota, with international offices in Canada, Colombia, Spain, India, Dubai, Australia, Singapore, and China. Founded in 1992, OSI is privately held and employee-owned. [1]