enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Drain-waste-vent system - Wikipedia

    en.wikipedia.org/wiki/Drain-waste-vent_system

    A sewer pipe is normally at neutral air pressure compared to the surrounding atmosphere.When a column of waste water flows through a pipe, it compresses air ahead of it in the system, creating a positive pressure that must be released so it does not push back on the waste stream and downstream traps, slow drainage, and induce potential clogs.

  3. Piping and instrumentation diagram - Wikipedia

    en.wikipedia.org/wiki/Piping_and_instrumentation...

    Permanent start-up, flush and bypass lines; Pipelines and flowlines; Blinds and spectacle blinds; Insulation and heat tracing; Process control instrumentation and designation (names, numbers, unique tag identifiers), including: Valves and their types and identifications (e.g. isolation, shutoff, relief and safety valves, valve interlocks)

  4. Drain (plumbing) - Wikipedia

    en.wikipedia.org/wiki/Drain_(plumbing)

    A drain cover is a cover with holes (e.g. a manhole) or a grating used to cover a drain, to prevent unwanted entry of foreign objects, or injury to people or animals. It allows drainage of liquids but prevents entry from large solid objects, and thus acts as a coarse filter. A sink drain cover is a drain cover used to cover the sink drain.

  5. Plumbing fixture - Wikipedia

    en.wikipedia.org/wiki/Plumbing_fixture

    The most common plumbing fixtures are: Bathtubs; Bidets; Channel drains; Drinking fountains; Showers; Sinks; Tap (connections for water hoses) . Tapware - an industry term for that sub-category of plumbing fixtures consisting of tap valves, also called water taps (British English) or faucets (American English), and their accessories, such as water spouts and shower heads.

  6. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    It is theoretically possible that, when both valves are faulty, backflow could occur, should the reverse flow rate exceed the capacity of the relief valve. Because certain combinations of check valve failure and/or system backpressure cause the relief valve to discharge, the device must be mounted in a location where the drain will not become ...

  7. Backflow - Wikipedia

    en.wikipedia.org/wiki/Backflow

    A recent introduction to the UK has been the Reduced Pressure Zone (RPZ) valve, a form of double check valve where the intervening zone is drained and normally kept empty. [1] If the downstream valve leaks and permits backflow, this will drain out through the vent rather than building up pressure against the upstream valve.

  8. Fixture unit - Wikipedia

    en.wikipedia.org/wiki/Fixture_unit

    A Fixture Unit is not a flow rate unit but a design factor. A fixture unit is equal to 1 cubic foot (0.028 m 3) of water drained in a 1 + 1 ⁄ 4 inches (32 mm) diameter pipe over one minute. [2] One cubic foot of water is roughly 7.48 US gallons (28.3 L; 6.23 imp gal). A Fixture Unit is used in plumbing design for both water supply and waste ...

  9. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.