Notice also that using the root mean square voltage =, the expression for above takes the following more classic form: P T O T = 3 V 2 R {\displaystyle P_{TOT}={\frac {3V^{2}}{R}}} . The load need not be resistive for achieving a constant instantaneous power since, as long as it is balanced or the same for all phases, it may be written as
The service factor is typically in the 1.15-1.4 range, with the figure being lower for higher-power motors. For every hour of operation at the service-factor-adjusted power rating, a motor loses two to three hours of life at nominal power, i.e. its service life is reduced to less than half for continued operation at this level.
Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. Three-phase electric power (abbreviated 3ϕ [1]) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. [2]
The standard includes preferred current ratings and wire gauges for both International (deemed Series I) and North American (deemed Series II) applications. Series I preferred current ratings (in amps) are: 16, 32, 63, 125, 250, 400, 630 and 800, with wire gauges specified as mm 2.
The other end of the three secondary windings and the neutral are brought down the service drop to the service panel. 230 V loads are connected between any of the three-phase wires and the neutral. Because the phases are 120 degrees from each other, the voltage between any two phases is sqrt(3) * 230V = 400V, compared to the 2 * 120V = 240V in ...
Each type specifies characteristics of an enclosure, but not, for example, a specific enclosure size. Note that higher numbers do not include the lower-numbered tests. For example, types 3, 4 and 6 are intended for outdoor use, but type 5 is not. A NEMA enclosure rating does not mean that it also meets the same UL enclosure rating. [2]
As an example, the 5-15R is the common 125 V two-pole, three-wire receptacle rated for 15 A. The L5-15R, while sharing the same electrical rating, is a locking design that is not physically compatible with the straight-blade 5-15 design. The 5-30R has the same two-pole, three-wire configuration and 125 V rating, but is rated for 30 A.
Since the different current ratings have different overall sizes, it is also not possible to mate different pin configurations or current ratings. For example, a 16 A 3P+E 400 V plug will not mate with a 16 A 3P+N+E 400 V socket and a 16 A P+N+E 230 V plug will not mate with a 32 A P+N+E 230 V socket.