Unfused spurs from a ring wired in the same cable as the ring are allowed to run one socket (single or double) or one fused connection unit (FCU). Before 1970 the use of two single sockets on one spur was allowed, but has since been disallowed because of their conversion to double sockets.
Switched and unswitched fused connection units, without sockets, use BS 1362 fuses for connection of permanently wired appliances to a socket-outlet circuit. They are also used in other situations where a fuse or switch (or both) is required, such as when feeding lighting off a socket-outlet circuit, to protect spurs off a ring circuit with ...
Wire crossover symbols for circuit diagrams. The CAD symbol for insulated crossing wires is the same as the older, non-CAD symbol for non-insulated crossing wires. To avoid confusion, the wire "jump" (semi-circle) symbol for insulated wires in non-CAD schematics is recommended (as opposed to using the CAD-style symbol for no connection), so as to avoid confusion with the original, older style ...
Flexible appliance cords require protection at a lower current than that provided by the final circuit overcurrent protection device. This additional protection device may be contained within either the appliance plug (by far the most common solution) or the connection unit (a fused socket or possibly a fused spur protecting the socket).
In an electrical power distribution system, a ring main unit (RMU) is a factory assembled, metal enclosed set of switchgear used at the load connection points of a ring-type distribution network. It includes in one unit two switches that can connect the load to either or both main conductors, and a fusible switch or circuit breaker and switch ...
The neutral is connected to the center tap of the power company transformer of a split-phase system, or the center of the wye connection of a polyphase power system. United States electrical codes require that the neutral be connected to earth at the "service panel" only and at no other point within the building wiring system.
(Fuse wire is commonly supplied to consumers as short lengths of 5 A-, 15 A- and 30 A-rated wire wound on a piece of cardboard.) Modern consumer units usually contain miniature circuit breakers (MCBs) instead of fuses, though cartridge fuses are sometimes still used, as in some applications MCBs are prone to nuisance tripping.
2009-07-27 18:55 Hydrargyrum 485×726 (4521 bytes) Changed symbol stroke weight from 5 px to 8 px; 2009-07-27 18:36 Hydrargyrum 485×726 (4598 bytes) {{Information |Description = Basic fuse symbols, per IEC and IEEE/ANSI standards |Source = I (~~~) created this work entirely by myself, based on ANSI Y32.2-1975, CSA Z99-1975 and IEEE Std. 315-1975 |Date = 27 July 2009 |Author