Search results
Results from the WOW.Com Content Network
Switched and unswitched fused connection units, without sockets, use BS 1362 fuses for connection of permanently wired appliances to a socket-outlet circuit. They are also used in other situations where a fuse or switch (or both) is required, such as when feeding lighting off a socket-outlet circuit, to protect spurs off a ring circuit with ...
1A1A44J5 - Unit 1, Assembly 1, Sub-Assembly 44, Jack 5 (J5 is a connector on a box referenced as A44) 1A1A45J333 - Unit 1, Assembly 1, Sub-Assembly 45, Jack 333 (J333 is a connector on a box referenced as A45) A cable connecting these two might be: 1A1W35 - In the assembly A1 is a cable called W35. Connectors on this cable would be designated:
Each type of switch has a different symbol and so do the various outlets. There are symbols that show the location of smoke detectors, the doorbell chime, and thermostat. On large projects symbols may be numbered to show, for example, the panel board and circuit to which the device connects, and also to identify which of several types of ...
The ring starts at the consumer unit (also known as fuse box, distribution board, or breaker box), visits each socket in turn, and then returns to the consumer unit. The ring is fed from a fuse or circuit breaker in the consumer unit. Ring circuits are commonly used in British wiring with socket-outlets taking fused plugs to BS 1363. Because ...
In an electrical power distribution system, a ring main unit (RMU) is a factory assembled, metal enclosed set of switchgear used at the load connection points of a ring-type distribution network. It includes in one unit two switches that can connect the load to either or both main conductors, and a fusible switch or circuit breaker and switch ...
Wire crossover symbols for circuit diagrams. The CAD symbol for insulated crossing wires is the same as the older, non-CAD symbol for non-insulated crossing wires. To avoid confusion, the wire "jump" (semi-circle) symbol for insulated wires in non-CAD schematics is recommended (as opposed to using the CAD-style symbol for no connection), so as to avoid confusion with the original, older style ...
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
2009-07-27 18:55 Hydrargyrum 485×726 (4521 bytes) Changed symbol stroke weight from 5 px to 8 px; 2009-07-27 18:36 Hydrargyrum 485×726 (4598 bytes) {{Information |Description = Basic fuse symbols, per IEC and IEEE/ANSI standards |Source = I (~~~) created this work entirely by myself, based on ANSI Y32.2-1975, CSA Z99-1975 and IEEE Std. 315-1975 |Date = 27 July 2009 |Author