enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Aluminium-conductor steel-reinforced cable - Wikipedia

    en.wikipedia.org/wiki/Aluminium-conductor_steel...

    An ACSR conductor can in part be denoted by its stranding, for example, an ACSR conductor with 72 aluminium strands with a core of 7 steel strands will be called 72/7 ACSR conductor. [ 3 ] [ 4 ] [ 5 ] Cables generally range from #6 AWG ("6/1" – six outer aluminum conductors and one steel reinforcing conductor) to 2167 kcmil ("72/7 ...

  3. Neher–McGrath method - Wikipedia

    en.wikipedia.org/wiki/Neher–McGrath_method

    The equation in section 310-15(C) of the National Electrical Code, called the Neher–McGrath equation (NM), may be used to estimate the effective ampacity of a cable: [3] = (+) (+), In the equation, T c {\textstyle T_{c}} is normally the limiting conductor temperature derived from the insulation or tensile strength limitations.

  4. ACCC conductor - Wikipedia

    en.wikipedia.org/wiki/ACCC_conductor

    Its light weight and softness result in roughly 30% greater conductivity than an equivalent ACSR conductor, allowing 14% more current to be carried at equal temperature. For example, 1.107 in (28.1 mm) diameter ACCC "Drake" conductor at 75 °C has an AC resistance of 106 mΩ/mile, [ 7 ] while equivalent ACSR conductor has an AC resistance of ...

  5. Electrical conductor - Wikipedia

    en.wikipedia.org/wiki/Electrical_conductor

    The ampacity of a conductor, that is, the amount of current it can carry, is related to its electrical resistance: a lower-resistance conductor can carry a larger value of current. The resistance, in turn, is determined by the material the conductor is made from (as described above) and the conductor's size.

  6. Dynamic line rating for electric utilities - Wikipedia

    en.wikipedia.org/wiki/Dynamic_line_rating_for...

    Several kinds of ratings may be made available, including: real-time, indicating ampacity immediately available, without time limits should conditions remain identical; emergency ratings for a limited duration; and same-day and day-ahead forecasts. DLR computations deal with "near real-time" data, updated about every five minutes.

  7. Circuit integrity - Wikipedia

    en.wikipedia.org/wiki/Circuit_integrity

    Circuit integrity fireproofing of cable trays using calcium silicate board system Circuit integrity fireproofing of cable trays Fire-resistant cables MI cables fastened into junction box that has not been fireproofed. Circuit integrity describes the extent of a fire's effect on an electrical circuit's operation. It is a form of fire-resistance ...

  8. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    For example, the United States National Electrical Code, Table 310.15(B)(16), specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30 °C, the conductor surface temperature allowed to be 75 °C. A single insulated conductor ...

  9. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...