A 0.5 McFarland standard is prepared by mixing 0.05 mL of 1.175% barium chloride dihydrate (BaCl 2 •2H 2 O), with 9.95 mL of 1% sulfuric acid (H 2 SO 4). [ 1 ] Now there are McFarland standards prepared from suspensions of latex particles, which lengthens the shelf life and stability of the suspensions.
In summary, in order to find a standard curve, one must use varying concentrations of BSA (Bovine Serum Albumin) [2] in order to create a standard curve with concentration plotted on the x-axis and absorbance plotted on the y-axis. Only a narrow concentration of BSA is used (2-10 ug/mL) in order to create an accurate standard curve. [23]
The enzyme unit, or international unit for enzyme (symbol U, sometimes also IU) is a unit of enzyme's catalytic activity. [ 1 ] 1 U (μmol/min) is defined as the amount of the enzyme that catalyzes the conversion of one micro mole of substrate per minute under the specified conditions of the assay method .
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
The "A260 unit" is used as a quantity measure for nucleic acids. One A260 unit is the amount of nucleic acid contained in 1 mL and producing an OD of 1. The same conversion factors apply, and therefore, in such contexts: 1 A260 unit dsDNA = 50 μg 1 A260 unit ssDNA = 33 μg 1 A260 unit ssRNA = 40 μg
Although there are examples to the contrary, it should be stressed that the commonly used "units" of % w/v are grams per millilitre (g/mL). 1% m/v solutions are sometimes thought of as being gram/100 mL but this detracts from the fact that % m/v is g/mL; 1 g of water has a volume of approximately 1 mL (at standard temperature and pressure) and ...
IC 50 is a quantitative measure that indicates how much of a particular inhibitory substance (e.g. drug) is needed to inhibit, in vitro, a given biological process or biological component by 50%. [1] The biological component could be an enzyme, cell, cell receptor or microbe. IC 50 values are typically expressed as molar concentration.
The free NCBI tool Primer-BLAST integrates primer design and BLAST search into one application, [6] as do commercial software products such as ePrime and Beacon Designer. Computer simulations of theoretical PCR results ( Electronic PCR ) may be performed to assist in primer design by giving melting and annealing temperatures, etc. [ 7 ]