Search results
Results from the WOW.Com Content Network
The following formulas can be used to calculate the volumes of solute (V solute) and solvent (V solvent) to be used: [1] = = where V total is the desired total volume, and F is the desired dilution factor number (the number in the position of F if expressed as "1/F dilution factor" or "xF dilution"). However, some solutions and mixtures take up ...
The dilution in welding terms is defined as the weight of the base metal melted divided by the total weight of the weld metal. For example, if we have a dilution of 0.40, the fraction of the weld metal that came from the consumable electrode is 0.60.
The heat of dilution can be defined from two perspectives: the differential heat and the integral heat. The differential heat of dilution is viewed on a micro scale, which is associated with the process in which a small amount of solvent is added to a large quantity of solution. The molar differential heat of dilution is thus defined as the enthalpy
A serial dilution is the step-wise dilution of a substance in solution, either by using a constant dilution factor, or by using a variable factor between dilutions. If the dilution factor at each step is constant, this results in a geometric progression of the concentration in a logarithmic fashion.
The rate of nutrient exchange is expressed as the dilution rate D. At steady state, the specific growth rate μ of the micro-organism is equal to the dilution rate D. The dilution rate is defined as the flow of medium per unit of time, F, over the volume V of culture in the bioreactor
Volume percent is the concentration of a certain solute, measured by volume, in a solution.It has as a denominator the volume of the mixture itself, as usual for expressions of concentration, [2] rather than the total of all the individual components’ volumes prior to mixing:
At greater dilutions the indirect Coombs test is negative. If a few weeks later the same patient had an indirect Coombs titer of 32 (1/32 dilution which is 1 part serum to 31 parts diluent), this would mean that she was making more anti-Rh antibody, since it took a greater dilution to abolish the positive test.
This depth is converted to a flow rate according to a theoretical formula of the form = where is the flow rate, is a constant, is the water level, and is an exponent which varies with the device used; or it is converted according to empirically derived level/flow data points (a "flow curve"). The flow rate can then be integrated over time into ...