enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    Strictly speaking, the terms grounding or earthing are meant to refer to an electrical connection to ground/earth. Bonding is the practice of intentionally electrically connecting metallic items not designed to carry electricity. This brings all the bonded items to the same electrical potential as a protection from electrical shock.

  3. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    The neutral conductor of a 3-phase, 4-wire system and the middle conductor of a 2- phase, 3-wire system must have at least 2 separate and distinct earth connections with a minimum of 2 different earth electrodes to have a satisfactory earth resistance; The earth electrodes must be interconnected to reduce earth resistance

  4. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    The first rubber-insulated cables for US building wiring were introduced in 1922 with US patent 1458803, Burley, Harry & Rooney, Henry, "Insulated electric wire", issued 1923-06-12, assigned to Boston Insulated Wire and Cable . These were two or more solid copper electrical wires with rubber insulation, plus woven cotton cloth over each ...

  5. Electrical bonding - Wikipedia

    en.wikipedia.org/wiki/Electrical_bonding

    Electrical bonding is the practice of intentionally electrically connecting all exposed metal items not designed to carry electricity in a room or building as protection from electric shock. Bonding is also used to minimize electrical arcing between metal surfaces with electrical potential differences.

  6. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    A separate pilot wire is run from distribution/ equipment supply system in addition to earth wire, to supervise the continuity of the wire. This is used in the trailing cables of mining machinery. [19] If the earth wire is broken, the pilot wire allows a sensing device at the source end to interrupt power to the machine.

  7. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  8. Multipoint ground - Wikipedia

    en.wikipedia.org/wiki/Multipoint_ground

    The amount of cross bonding, and the topology of the grids, is determined by the expected frequencies in the signals to be carried and the uses the installation will be put to. A ground grid is provided primarily for safety, and the size of the conductors is probably governed by local building or electrical code. One factor to keep in mind is ...

  9. TIA-607-B - Wikipedia

    en.wikipedia.org/wiki/TIA-607-B

    Among TIA-607-B's list of metallic components in need of bonding are racks, enclosures, ladders, surge protectors, cable trays, routers, switches and patch panels. Following the bonding of telecom infrastructure components, the entire system must be bonded to the building's main ground, which is sometimes also referred to as a grounding ...