In electrical engineering, Neher–McGrath is a method of estimating the steady-state temperature of electrical power cables for some commonly encountered configurations. By estimating the temperature of the cables, the safe long-term current-carrying capacity of the cables can be calculated.
Electric kettle: more than 90% [citation needed] (comparatively little heat energy is lost during the 2 to 3 minutes a kettle takes to boil water). A premium efficiency electric motor: more than 90% (see Main Article: Premium efficiency). A large power transformer used in the electrical grid may have efficiency of more than 99%. Early 19th ...
Efficiency of power plants, world total, 2008. Energy conversion efficiency (η) is the ratio between the useful output of an energy conversion machine and the input, in energy terms. The input, as well as the useful output may be chemical, electric power, mechanical work, light (radiation), or heat. The resulting value, η (eta), ranges ...
Together, the price duration curve and load duration curve enable the analyst to understand the behaviour of the electricity market, for example, the likelihood of peaking power plant being required for service, and the impact that this might have on price. Mathematically, it is a complementary cumulative distribution function.
Pinch analysis is a methodology for minimising energy consumption of chemical processes by calculating thermodynamically feasible energy targets (or minimum energy consumption) and achieving them by optimising heat recovery systems, energy supply methods and process operating conditions.
Peukert's law becomes a key issue in a battery electric vehicle, where batteries rated, for example, at a 20-hour discharge time are used at a much shorter discharge time of about 1 hour. At high load currents the internal resistance of a real battery dissipates significant power, reducing the power (watts) available to the load in addition to ...
In an electrical grid, the short circuit ratio (or SCR) is the ratio of: the short circuit apparent power (SCMVA) in the case of a line-line-line-ground (3LG) fault at the location in the grid where some generator is connected, to: the power rating of the generator itself (GMW).
Since the losses in the wires are proportional to the square of the current (and thus the square of the power), the LLF can be calculated by measuring the square of delivered power over a short interval of time (typically half an hour), calculating an average of these values over a long period (a year), and dividing by the square of the peak ...