Search results
Results from the WOW.Com Content Network
The main components of a split-system (called split as there are both inside and outside coils) air source heat pump are: An outdoor evaporator heat exchanger coil, which extracts heat from ambient air; One or more [10] indoor condenser heat exchanger coils. They transfer the heat into the indoor air, or an indoor heating system such as water ...
Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...
Tubular heat exchanger Partial view into inlet plenum of shell and tube heat exchanger of a refrigerant based chiller for providing air-conditioning to a building. A heat exchanger is a system used to transfer heat between a source and a working fluid. Heat exchangers are used in both cooling and heating processes. [1]
Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...
Diagram of natural draft gas furnace, early 20th century. The first category of furnaces is natural draft, atmospheric burner furnaces. These furnaces consisted of cast-iron or riveted-steel heat exchangers built within an outer shell of brick, masonry, or steel. The heat exchangers were vented through brick or masonry chimneys.
The airflow is then reversed, so that the hot bricks heat up the incoming combustion air and fuel. For a glass-melting furnace, a regenerator sits on either side of the furnace, often forming an integral whole. For a blast furnace, the regenerators (commonly called Cowper stoves) sit separate to the furnace. A furnace needs no less than two ...
Regardless of type, all air handlers consist of an air filter, blower, heat exchanger/element/coil, and various controls. Like any other kind of central heating system, thermostats are used to control forced air heating systems. Forced air heating is the type of central heating most commonly installed in North America. [1]
Older furnaces sometimes relied on gravity instead of a blower to circulate air. [1]Gas-fired forced-air furnaces have a burner in the furnace fueled by natural gas.A blower forces cold air through a heat exchanger and then through duct-work that distributes the hot air through the building. [2]