enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Henderson–Hasselbalch equation - Wikipedia

    en.wikipedia.org/wiki/Henderson–Hasselbalch...

    The Henderson–Hasselbalch equation relates the pH of a solution containing a mixture of the two components to the acid dissociation constant, K a of the acid, and the concentrations of the species in solution. [6] Simulated titration of an acidified solution of a weak acid (pK a = 4.7) with alkali

  3. Acid dissociation constant - Wikipedia

    en.wikipedia.org/wiki/Acid_dissociation_constant

    The solution is then titrated with a strong base until all the protons have been removed. At each point in the titration pH is measured using a glass electrode and a pH meter. The equilibrium constants are found by fitting calculated pH values to the observed values, using the method of least squares. [59]

  4. pH - Wikipedia

    en.wikipedia.org/wiki/PH

    At 25 °C (77 °F), solutions of which the pH is less than 7 are acidic, and solutions of which the pH is greater than 7 are basic. Solutions with a pH of 7 at 25 °C are neutral (i.e. have the same concentration of H + ions as OH − ions, i.e. the same as pure water). The neutral value of the pH depends on the temperature and is lower than 7 ...

  5. Gran plot - Wikipedia

    en.wikipedia.org/wiki/Gran_plot

    The pH meter is usually calibrated with buffer solutions at known pH values before starting the titration. The ionic strength can be kept constant by judicious choice of acid and base. For instance, HCl titrated with NaOH of approximately the same concentration will replace H + with an ion (Na + ) of the same charge at the same concentration ...

  6. Phosphate-buffered saline - Wikipedia

    en.wikipedia.org/wiki/Phosphate-buffered_saline

    Add 2.84 mM of HCl to shift the buffer to 7.3 mM HPO 4 2− and 4.6 mM H 2 PO 4 − for a final pH of 7.4 and a Cl − concentration of 142 mM. The pH of PBS is ~7.4. When making buffer solutions, it is good practice to always measure the pH directly using a pH meter. If necessary, pH can be adjusted using hydrochloric acid or sodium hydroxide.

  7. Determination of equilibrium constants - Wikipedia

    en.wikipedia.org/wiki/Determination_of...

    Hydrolysis constants of metal ions are usually fixed at values which were obtained using ligand-free solutions. When determining the stability constants for ternary complexes, M p A q B r it is common practice the fix the values for the corresponding binary complexes M p′ A q′ and M p′′ B q′′ , at values which have been determined ...

  8. Weak base - Wikipedia

    en.wikipedia.org/wiki/Weak_base

    Bases are proton acceptors; a base will receive a hydrogen ion from water, H 2 O, and the remaining H + concentration in the solution determines pH. A weak base will have a higher H + concentration than a stronger base because it is less completely protonated than a stronger base and, therefore, more hydrogen ions remain in its solution.

  9. Acid–base titration - Wikipedia

    en.wikipedia.org/wiki/Acid–base_titration

    The pH after the equivalence point depends on the concentration of the conjugate base of the weak acid and the strong base of the titrant. However, the base of the titrant is stronger than the conjugate base of the acid. Therefore, the pH in this region is controlled by the strong base. As such the pH can be found using the following: [1]