Search results
Results from the WOW.Com Content Network
C = Concentration of the chemical in the contaminated environmental medium (soil or water) to which the person is exposed. The units are mg/kg for soil and mg/L for water. IR i = Intake rate of the contaminated environmental medium for age bin "i". The units are kg/day for soil and L/day for water. BW i = Body weight of the exposed person for ...
where TDS is expressed in mg/L and EC is the electrical conductivity in microsiemens per centimeter at 25 °C. The conversion factor k e varies between 0.55 and 0.8. [5] Some TDS meters use an electrical conductivity measurement to the ppm using the above formula. Regarding units, 1 ppm indicates 1 mg of dissolved solids per 1,000 g of water. [6]
1 Nm 3 of any gas (measured at 0 °C and 1 atmosphere of absolute pressure) equals 37.326 scf of that gas (measured at 60 °F and 1 atmosphere of absolute pressure). 1 kmol of any ideal gas equals 22.414 Nm 3 of that gas at 0 °C and 1 atmosphere of absolute pressure ... and 1 lbmol of any ideal gas equals 379.482 scf of that gas at 60 °F and ...
Normality is defined as the number of gram or mole equivalents of solute present in one liter of solution.The SI unit of normality is equivalents per liter (Eq/L). = where N is normality, m sol is the mass of solute in grams, EW sol is the equivalent weight of solute, and V soln is the volume of the entire solution in liters.
C h = Concentration, in mass per unit volume at altitude h and specified temperature T As an example, given an air pollutant concentration of 260 mg/m 3 at sea level, calculate the equivalent pollutant concentration at an altitude of 2800 meters:
If milliliters are used consistently for volume measurements, the result of the COD calculation is given in mg/L. The COD can also be estimated from the concentration of oxidizable compound in the sample, based on its stoichiometric reaction with oxygen to yield CO 2 (assume all C goes to CO 2 ), H 2 O (assume all H goes to H 2 O), and NH 3 ...
For some usage examples, consider the conversion of 1 SCCM to kg/s of a gas of molecular weight , where is in kg/kmol. Furthermore, consider standard conditions of 101325 Pa and 273.15 K, and assume the gas is an ideal gas (i.e., Z n = 1 {\displaystyle Z_{n}=1} ).
For example, according to the capacitance row of the table, if a capacitor has a capacitance of 1 F in SI, then it has a capacitance of (10 −9 c 2) cm in ESU; but it is incorrect to replace "1 F" with "(10 −9 c 2) cm" within an equation or formula. (This warning is a special aspect of electromagnetism units.