Search results
Results from the WOW.Com Content Network
For common tape measurements, the tape used is a steel tape with coefficient of thermal expansion C equal to 0.000,011,6 units per unit length per degree Celsius change. This means that the tape changes length by 1.16 mm per 10 m tape per 10 °C change from the standard temperature of the tape.
The CLTD/CLF/SCL (cooling load temperature difference/cooling load factor/solar cooling load factor) cooling load calculation method was first introduced in the 1979 ASHRAE Cooling and Heating Load Manual (GRP-158) [1] The CLTD/CLF/SCL Method is regarded as a reasonably accurate approximation of the total heat gains through a building envelope ...
Electric heat tracing, heat tape or surface heating, is a system used to maintain or raise the temperature of pipes and vessels using heat tracing cables. Trace heating takes the form of an electrical heating element run in physical contact along the length of a pipe.
The EU standard test conditions for an air source heat pump is at dry-bulb temperature of 20 °C (68 °F) for and 7 °C (44.6 °F) for . [9] Given sub-zero European winter temperatures, real world heating performance is significantly poorer than such standard COP figures imply.
The building balance point temperature is the outdoor air temperature when the heat gains of the building are equal to the heat losses. [1] Internal heat sources due to electric lighting, mechanical equipment, body heat, and solar radiation may offset the need for additional heating although the outdoor temperature may be below the thermostat set-point temperature.
In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.
In soldering, a thermal profile is a complex set of time-temperature values for a variety of process dimensions such as slope, soak, TAL, and peak. [8] Solder paste contains a mix of metal, flux, and solvents that aid in the phase change of the paste from semi-solid, to liquid to vapor; and the metal from solid to liquid.
Operative temperature is used in heat transfer and thermal comfort analysis in transportation and buildings. [10] Most psychrometric charts used in HVAC design only show the dry bulb temperature on the x-axis(abscissa), however, it is the operative temperature which is specified on the x-axis of the psychrometric chart illustrated in ANSI/ASHRAE Standard 55 – Thermal Environmental Conditions ...