A vapor barrier on the warm side of the envelope must be combined with a venting path on the cold side of the insulation. This is because no vapor barrier is perfect, and because water may get into the structure, typically from rain. In general, the better the vapor barrier and the drier the conditions, the less venting is required. [7]
Concrete normally allows moisture to pass through so a vertical vapor barrier is needed. Barriers may be a coating or membrane applied to the exterior of the concrete. The coating may be asphalt, asphalt emulsion, a thinned asphalt called cutback asphalt, or an elastomer. [9] Membranes are rubberized asphalt or EPDM rubber. Rubberized products ...
The drainage system collects any water entering the basement and drains it to an internally placed sump pump system, which will then pump the water out of the basement. The Federal Emergency Management Agency (FEMA) recommends basement waterproofing with a water alarm and "battery-operated backup pump" as a preventive measure against the high ...
In order to achieve these objectives, all building enclosure systems must include a solid structure, a drainage plane, an air barrier, a thermal barrier, and may include a vapor barrier. Moisture control (e.g. damp proofing) is essential in all climates, but cold climates and hot-humid climates are especially demanding. [8]
Closed-cell foam is non-porous, and not moisture-penetrable, thereby effectively forming a semi-permeable vapor barrier. (N.B., vapor barriers are usually required by the Building Codes, regardless of the type of insulation used. Check with the local authorities to find out the requirements for your area.) Closed-cell foams are superior insulators.
Walls also have vapor barriers or air barriers. Damp proofing is another aspect of waterproofing. Masonry walls are built with a damp-proof course to prevent rising damp , and the concrete in foundations needs to be damp-proofed or waterproofed with a liquid coating, basement waterproofing membrane (even under the concrete slab floor where ...
using an diffusion tight vapor barrier (vapor check) on the warm side of the insulation, i.e., inside the assembly on a heated building and outside on a cooled building. [4] Vapor barriers can be problematic because they difficult to install perfectly and also reduce the ability of a cavity to dry out when it does get wet.
More recently, finished space has become increasingly acceptable as a measure which includes the developed basement areas of a home. Due to fire code requirements, most jurisdictions require an emergency egress (through either egress-style windows, or, in the case of a walk-out basement, a door) to include the basement square footage as living ...