enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Titration - Wikipedia

    en.wikipedia.org/wiki/Titration

    Back titration is a titration done in reverse; instead of titrating the original sample, a known excess of standard reagent is added to the solution, and the excess is titrated. A back titration is useful if the endpoint of the reverse titration is easier to identify than the endpoint of the normal titration, as with precipitation reactions

  3. Argentometry - Wikipedia

    en.wikipedia.org/wiki/Argentometry

    An example of back titration, the Volhard method, named after Jacob Volhard, involves the addition of excess silver nitrate to the analyte; the silver chloride is filtered, and the remaining silver nitrate is titrated against ammonium thiocyanate, [1] with ferric ammonium sulfate as an indicator which forms blood-red [Fe(OH 2) 5 (SCN)] 2+ at the end point:

  4. Thermometric titration - Wikipedia

    en.wikipedia.org/wiki/Thermometric_titration

    Fig. 15. Titration plot of back-titration of excess EDTA with Cu(II) in NH 3 /NH 4 Cl buffered solution. Direct EDTA titrations with metal ions are possible when reaction kinetics are fast, for example zinc, copper, calcium and magnesium. However, with slower reaction kinetics such as those exhibited by cobalt and nickel, back-titrations are used.

  5. Chemistry of ascorbic acid - Wikipedia

    en.wikipedia.org/wiki/Chemistry_of_ascorbic_acid

    This indicates the end-point of the titration. As an alternative, ascorbic acid can be treated with iodine in excess, followed by back titration with sodium thiosulfate using starch as an indicator. [25] This iodometric method has been revised to exploit the reaction of ascorbic acid with iodate and iodide in acid solution. Electrolyzing the ...

  6. Kjeldahl method - Wikipedia

    en.wikipedia.org/wiki/Kjeldahl_method

    If boric acid (or some other weak acid) was used, direct acid–base titration is done with a strong acid of known concentration. HCl or H 2 SO 4 can be used. Indirect back titration is used instead if strong acids were used to make the standard acid solution: strong base of known concentration (like NaOH) is used to neutralize the solution. In ...

  7. Permanganometry - Wikipedia

    en.wikipedia.org/wiki/Permanganometry

    It is a redox titration that involves the use of permanganates to measure the amount of analyte present in unknown chemical samples. [1] It involves two steps, namely the titration of the analyte with potassium permanganate solution and then the standardization of potassium permanganate solution with standard sodium oxalate solution. The ...

  8. Should You Use Ice or Heat for Your Back Pain? - AOL

    www.aol.com/lifestyle/ice-heat-back-pain...

    Ice can be used for back discomfort when there is a clear injury or irritation after moving in a suboptimal way that generates pain, says Dr. Shah. “However, other cold alternatives can also be ...

  9. Conductometry - Wikipedia

    en.wikipedia.org/wiki/Conductometry

    Conductometry has notable application in analytical chemistry, where conductometric titration is a standard technique. In usual analytical chemistry practice, the term conductometry is used as a synonym of conductometric titration while the term conductimetry is used to describe non-titrative applications. [1]