Tonometry is the procedure that eye care professionals perform to determine the intraocular pressure (IOP), the fluid pressure inside the eye. It is an important test in the evaluation of patients at risk from glaucoma . [ 1 ]
Intraocular pressure (IOP) is the fluid pressure inside the eye. Tonometry is the method eye care professionals use to determine this. IOP is an important aspect in the evaluation of patients at risk of glaucoma. [1] Most tonometers are calibrated to measure pressure in millimeters of mercury .
The Schiotz tonometer consists of a curved footplate which is placed on the cornea of a supine patient. A weighted plunger attached to the footplate sinks into the cornea. A scale then gives a reading depending on how much the plunger sinks into the cornea, and a conversion table converts the scale reading into IOP measured in mmHg.
Armand Imbert (1850-1922) and Adolf Fick (1829-1901) both demonstrated, independently of each other, that in ocular tonometry the tension of the wall can be neutralized when the application of the tonometer produces a flat surface instead of a convex one, and the reading of the tonometer (P) then equals (T) the IOP," whence all forces cancel each other.
Simple manual equipment can be used such as in the tangent screen test or the Amsler grid. When dedicated machinery is used it is called a perimeter. The exam may be performed by a technician in one of several ways. The test may be performed by a technician directly, with the assistance of a machine, or completely by an automated machine.
The Heidelberg Retinal Tomography is a diagnostic procedure used in ophthalmology.The Heidelberg Retina Tomograph (HRT) is an ophthalmological confocal point scanning laser ophthalmoscope [1] for examining the cornea and certain areas of the retina using different diagnostic modules (HRT retina, HRT cornea, HRT glaucoma).
Intraocular pressure (IOP) can be measured by tonometry devices. The eye can be thought of as an enclosed compartment through which there is a constant circulation of fluid that maintains its shape and internal pressure. Tonometry is a method of measuring this pressure using various instruments. The normal range is 10-21 mmHg.
Electronystagmography (ENG) is a diagnostic test to record involuntary movements of the eye caused by a condition known as nystagmus. It can also be used to diagnose the cause of vertigo, dizziness or balance dysfunction by testing the vestibular system. [1] Electronystagmography is used to assess voluntary and involuntary eye movements. [2]