    An insulation monitoring device monitors the ungrounded system between an active phase conductor and earth.It is intended to give an alert (light and sound) or disconnect the power supply when the resistance between the two conductors drops below a set value, usually 50 kΩ (sample of IEC standard for medical applications).

  3. Fault indicator - Wikipedia

    en.wikipedia.org/wiki/Fault_indicator

    Ground fault indicators for isolated ground systems sense the vector sum of the current and look for an imbalance indicating a fault on one or more of the three phases. Systems with earthing through high resistance have low phase-to-ground fault currents so require high sensitivity of FI [clarification needed]. When there are high load currents ...

  4. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    Three-phase transformers and their associated neutrals are usually found in industrial distribution environments. A system could be made entirely ungrounded. In this case a fault between one phase and ground would not cause any significant current. Commonly the neutral is grounded (earthed) through a bond between the neutral bar and the earth bar.

  5. Ground continuity monitor - Wikipedia

    en.wikipedia.org/wiki/Ground_continuity_monitor

    A GCM or ground continuity monitor (also called a ground integrity monitor or ground continuity tester) is an electrical safety device that monitors the impedance to ground of a temporary electrical circuit and can provide indication (or protective trip) in the event impedance rises to an unsafe value. A GCM is either an external testing device ...

  6. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker. In three-phase systems, a fault may involve one or more phases and ground, or may occur only between phases. In a "ground fault" or "earth fault", current flows into the earth.

  7. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or current flowing to another powered conductor.

  8. Grounding transformer - Wikipedia

    en.wikipedia.org/wiki/Grounding_transformer

    Provide a relatively low-impedance path to ground, thereby maintaining the system neutral at or near ground potential. [3] Limit the magnitude of transient over voltages when restriking ground faults occur. Provide a source of ground fault current during line-to-ground faults. Permit the connection of phase-to-neutral loads when desired. [2]

  9. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Earth fault protection also requires current transformers and senses an imbalance in a three-phase circuit. Normally the three phase currents are in balance, i.e. roughly equal in magnitude. If one or two phases become connected to earth via a low impedance path, their magnitudes will increase dramatically, as will current imbalance.