Adenoid hypertrophy, also known as enlarged adenoids refers to an enlargement of the adenoid (pharyngeal tonsil) that is linked to nasopharyngeal mechanical blockage and/or chronic inflammation. [1] Adenoid hypertrophy is a characterized by hearing loss , recurrent otitis media , mucopurulent rhinorrhea , chronic mouth breathing , nasal airway ...
In anatomy, the pharyngeal tonsil, also known as the nasopharyngeal tonsil or adenoid, is the superior-most of the tonsils. It is a mass of lymphoid tissue located behind the nasal cavity , in the roof and the posterior wall of the nasopharynx , [ 1 ] where the nose blends into the throat .
In this position both the head and neck are extended. This is done by keeping a sand bag under the supine patient's shoulder blade. For a patient with a kyphosis or a stiff neck, the head piece of the table is raised so that the head ring really does support the head. Its contraindicated in patients with Down syndrome owing to atlanto-axial ...
An x-ray beam is angled at 45° to the orbitomeatal line. The rays pass from behind the head and are perpendicular to the radiographic plate. Another variation of the waters places the orbitomeatal line at a 37° angle to the image receptor. It is named after the American radiologist Charles Alexander Waters.
Caldwell's view (or Occipitofrontal view) is a radiographic view of the skull where the X-ray plate is perpendicular to the orbitomeatal line. The rays pass from behind the head and are angled at 15-20° to the radiographic plate. It is commonly used to get better view of the ethmoid and frontal sinuses. [1]
A radiation source is positioned behind the patient at a standard distance (most often 6 feet, 1,8m), and the x-ray beam is fired toward the patient. In anteroposterior (AP) views, the positions of the x-ray source and detector are reversed: the x-ray beam enters through the anterior aspect and exits through the posterior aspect of the chest.
X-ray diffraction topography is one variant of X-ray imaging, making use of diffraction contrast rather than absorption contrast which is usually used in radiography and computed tomography (CT). Topography is exploited to a lesser extent with neutrons , and is the same concept as dark field imaging in an electron microscope .
The images may also be used to check for other requirements of some types of treatment, such as full or empty bladder, empty rectum, etc. [8] [27] The same cone beam beam source and detector can alternatively be used to take simple X-ray positioning images if the organ shows particularly well on X-ray or if Fiducial markers have been inserted ...