Search results

  1. Results from the WOW.Com Content Network
  2. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    NFPA Clean Agent Retention testing (this type of testing is usually described as a door fan test rather than a blower door test) Duct leakage testing of forced air heating/cooling systems - both supply (vents) ducts and return ducts can be tested to determine if and how much they leak air. A duct test can be combined with a blower door test to ...

  3. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    Duct leakage test in the US. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.

  4. Air door - Wikipedia

    en.wikipedia.org/wiki/Air_door

    A typical commercial air curtain enclosure. In North America, the more commonly-used term for an air door is "air curtain". The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) defines an air door as follows: "In its simplest application, an air curtain is a continuous broad stream of air circulated across a doorway of a conditioned space.

  5. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    The most common technique to measure airtightness is the fan pressurization method, also known as the blower door test. It is measured by the number of air changes per hour (ACH) that occur when there is a differential pressure of 50 pascals between outside and inside the building.

  6. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.

  7. Infiltration (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Infiltration_(HVAC)

    Smoke candles and blower-door tests can help identify less-than-obvious leaks. The Weatherization article describes methods for energy savings further. If infiltration is reduced below 0.35 ACH, it is recommended that mechanical ventilation (typically an exhaust fan or heat recovery ventilation ) be implemented.

  8. The 3 Most Overpriced Cities in America, According to Gen Z ...

    www.aol.com/3-most-overpriced-cities-america...

    Despite higher wages, the cost of living in New York, including housing, transportation and taxes, creates financial strain. Consider This: 20 Best Cities Where You Can Buy a House for Under $100K 2.

  9. Centrifugal fan - Wikipedia

    en.wikipedia.org/wiki/Centrifugal_fan

    Figure 1: Components of a centrifugal fan An external motor belt driven inline centrifugal fan discharging inline to the exterior of a building through a duct. Unlike non-inline/non-concentric impeller casing design with a cutoff blade above, the concentrically symetric cylinder casing and impeller geometry of inline type redirects the outflow around so that it is parallel to the inflow of gases.