  2. Pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Pressure_measurement

    Liquid-column pressure gauges have a highly linear calibration. They have poor dynamic response because the fluid in the column may react slowly to a pressure change. When measuring vacuum, the working liquid may evaporate and contaminate the vacuum if its vapor pressure is too high. When measuring liquid pressure, a loop filled with gas or a ...

  3. Deadweight tester - Wikipedia

    en.wikipedia.org/wiki/Deadweight_tester

    A dead weight tester (DWT) is a calibration standard method that uses a piston cylinder on which a load is placed to make an equilibrium with an applied pressure underneath the piston. Deadweight testers are secondary standards which means that the pressure measured by a deadweight tester is defined through other quantities: length, mass and ...

  4. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    Automatic calibration - A U.S. serviceman using a 3666C auto pressure calibrator. An automatic pressure calibrator [13] is a device that combines an electronic control unit, a pressure intensifier used to compress a gas such as Nitrogen, a pressure transducer used to detect desired levels in a hydraulic accumulator, and accessories such as ...

  5. Mercury pressure gauge - Wikipedia

    en.wikipedia.org/wiki/Mercury_pressure_gauge

    Gauges for measuring pressure in the range 20–30 standard atmospheres (15,000–23,000 mmHg) have been built. [13] A 23-metre-tall mercury column is difficult to read and suffers from inaccuracies caused by different parts of the column being at different temperatures. A more compact mercury pressure gauge suitable for high pressure was built ...

  6. Pirani gauge - Wikipedia

    en.wikipedia.org/wiki/Pirani_gauge

    A special form of the Pirani gauge is the pulsed Pirani vacuum gauge where the sensor wire is not operated at a constant temperature, but is cyclically heated up to a certain temperature threshold by an increasing voltage ramp. When the threshold is reached, the heating voltage is switched off and the sensor cools down again.

  7. Hydrostatic test - Wikipedia

    en.wikipedia.org/wiki/Hydrostatic_test

    Hydrostatic tests are conducted under the constraints of either the industry's or the customer's specifications, or may be required by law. The vessel is filled with a nearly incompressible liquid – usually water or oil – pressurised to test pressure, and examined for leaks or permanent changes in shape.

  8. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  9. Hot-filament ionization gauge - Wikipedia

    en.wikipedia.org/wiki/Hot-filament_ionization_gauge

    A glass envelope with an opening to the vacuum can surround the electrodes, but usually the nude gauge is inserted in the vacuum chamber directly, the pins being fed through a ceramic plate in the wall of the chamber. Hot-cathode gauges can be damaged or lose their calibration if they are exposed to atmospheric pressure or even low vacuum while ...