  1. Results from the WOW.Com Content Network
  2. Current sensing - Wikipedia

    en.wikipedia.org/wiki/Current_sensing

    The design of the saturable inductor current sensor is similar to that of a closed-loop Hall-effect current sensor; the only difference is that this method uses the saturable inductor instead of the Hall-effect sensor in the air gap. Saturable inductor current sensor is based on the detection of an inductance change. The saturable inductor is ...

  3. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    Residual current refers to any residue when comparing current in the outbound and return currents in the circuit. In a single phase circuit this is simply the live or phase current minus the neutral current. In a 3 phase circuit all current carrying conductors must be sensed.

  4. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    Instantaneous tripping current B 3–5 times rated current I n, e.g. a nominally 10 A device will trip at 30–50 A C 5–10 times I n: D 10–14 times I n: K 8–12 times I n. For the protection of loads that cause frequent short-duration (approximately 400 ms to 2 s) current peaks in normal operation Z

  5. Current transformer - Wikipedia

    en.wikipedia.org/wiki/Current_transformer

    Current transformers used to sense ground fault (zero sequence) currents, such as in a three-phase installation, may have three primary conductors passed through the ring. Only the net unbalanced current produces a secondary current - this can be used to detect a fault from an energized conductor to ground.

  6. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Earth fault protection also requires current transformers and senses an imbalance in a three-phase circuit. Normally the three phase currents are in balance, i.e. roughly equal in magnitude. If one or two phases become connected to earth via a low impedance path, their magnitudes will increase dramatically, as will current imbalance.

  7. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    On a 3-phase circuit, a recloser is more beneficial than three separate fuse cutouts. For example, on a wye to delta conversion, when cutouts are used on the wye side and only 1 out of 3 of the cutout fuses open, some customers on the delta side have a low voltage condition, due to voltage transfer through the transformer windings. Low voltage ...