enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Pacesetter Systems - Wikipedia

    en.wikipedia.org/wiki/Pacesetter_Systems

    Pacesetter Systems Inc. was a biotechnology company founded by Alfred E. Mann in 1965. The company manufactured various implantable medical devices invented by Robert Fischell and the rest of the team at the Johns Hopkins University Applied Physics Laboratory.

  3. Artificial cardiac pacemaker - Wikipedia

    en.wikipedia.org/wiki/Artificial_cardiac_pacemaker

    As of 2014 the five most commonly used cardiac pacing device manufacturers (covering more than 99% of the US market) made FDA-approved MR-conditional pacemakers. [34] The use of MRI may be ruled out by the patient having an older, non-MRI Conditional pacemaker, or by having old pacing wires inside the heart, no longer connected to a pacemaker.

  4. St. Jude Medical - Wikipedia

    en.wikipedia.org/wiki/St._Jude_Medical

    St. Jude Medical was founded in 1976 to further develop bi-leaflet artificial heart valves, which were originally created in 1972 at the University of Minnesota. [4] [5] St. Jude Medical's bi-leaflet valve was developed in large part by Dr. Demetre Nicoloff of the University of Minnesota and St. Jude Medical employee Don Hanson.

  5. Medtronic Wins FDA Approval for MRI-Accessible Pacemaker - AOL

    www.aol.com/news/2013-02-14-medtronic-wins-fda...

    Patients with pacemakers in the U.S. had previously been dissuaded from using MRIs before Medtronic's first SureScan MRI-compatible pacemaker won approval a few years ago.

  6. Safety of magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Safety_of_magnetic...

    All patients are reviewed for contraindications prior to MRI scanning. Medical devices and implants are categorized as MR Safe, MR Conditional or MR Unsafe: [6] MR-Safe – The device or implant is completely non-magnetic, non-electrically conductive, and non-RF reactive, eliminating all of the primary potential threats during an MRI procedure.

  7. Cardiac magnetic resonance imaging perfusion - Wikipedia

    en.wikipedia.org/wiki/Cardiac_magnetic_resonance...

    Cardiac magnetic resonance imaging perfusion (cardiac MRI perfusion, CMRI perfusion), also known as stress CMR perfusion, [1] is a clinical magnetic resonance imaging test performed on patients with known or suspected coronary artery disease to determine if there are perfusion defects in the myocardium of the left ventricle that are caused by narrowing of one or more of the coronary arteries.

  8. Implantable cardioverter-defibrillator - Wikipedia

    en.wikipedia.org/wiki/Implantable_cardioverter...

    The difference between pacemakers and ICDs is that pacemakers are also available as temporary units and are generally designed to correct slow heart rates, i.e. bradycardia, while ICDs are often permanent safeguards against sudden life-threatening arrhythmias. S-ICD lead and generator position Sketch of an already-implanted cardioverter ...

  9. Template:Table of MRI sequences - Wikipedia

    en.wikipedia.org/wiki/Template:Table_of_MRI...

    Steady-state free precession: SSFP: Maintenance of a steady, residual transverse magnetisation over successive cycles. [7] Creation of cardiac MRI videos (pictured). [7] Effective T2 or "T2-star" T2* Spoiled gradient recalled echo (GRE) with a long echo time and small flip angle [8] Low signal from hemosiderin deposits (pictured) and ...