Search results
Results from the WOW.Com Content Network
Gene length: Longer genes will have more fragments/reads/counts than shorter genes if transcript expression is the same. This is adjusted by dividing the FPM by the length of a feature (which can be a gene, transcript, or exon), resulting in the metric fragments per kilobase of feature per million mapped reads (FPKM). [90]
Sequencing technologies vary in the length of reads produced. Reads of length 20-40 base pairs (bp) are referred to as ultra-short. [2] Typical sequencers produce read lengths in the range of 100-500 bp. [3] However, Pacific Biosciences platforms produce read lengths of approximately 1500 bp. [4] Read length is a factor which can affect the results of biological studies. [5]
The restriction fragments are then ligated together. [31] A molecular marker is then generated when specific fragments are selected for amplification. AFLP markers are run alongside a DNA marker on a gel. A common AFLP DNA marker is 30-330bp long. [32] The fragments of this marker lie at 10bp intervals to increase precision. RAPD
In bioinformatics, sequence assembly refers to aligning and merging fragments from a longer DNA sequence in order to reconstruct the original sequence. [1] This is needed as DNA sequencing technology might not be able to 'read' whole genomes in one go, but rather reads small pieces of between 20 and 30,000 bases, depending on the technology used. [1]
The entire set of fragments must be cloned together with the vector, and separation of clones can occur after. In either case, the fragments are ligated into a vector that has been digested with the same restriction enzyme. The vector containing the inserted fragments of genomic DNA can then be introduced into a host organism. [1]
A restriction fragment is a DNA fragment resulting from the cutting of a DNA strand by a restriction enzyme (restriction endonucleases), a process called restriction. [1] Each restriction enzyme is highly specific, recognising a particular short DNA sequence, or restriction site, and cutting both DNA strands at specific points within this site.
While single-read accuracy is 87%, consensus accuracy has been demonstrated at 99.999% with multi-kilobase read lengths. [ 37 ] [ 38 ] In 2015, Pacific Biosciences released a new sequencing instrument called the Sequel System, which increases capacity approximately 6.5-fold.
[4] [16] [17] Fragments of this size are suitable for high-throughput sequencing. [4] [16] [17] Following sonication, fragments can be size selected using AMPure XP beads from Beckman Coulter to obtain ligation products with a size distribution between 150 and 300 bp. [4] [17] This is the optimal fragment size window for HiSeq cluster formation ...