Search results

  1. Results from the WOW.Com Content Network
  2. Failure detector - Wikipedia

    en.wikipedia.org/wiki/Failure_detector

    The construction of a failure detector is an essential, but a very difficult problem that occurred in the development of the fault-tolerant component in a distributed computer system. As a result, the failure detector was invented because of the need for detecting errors in the massive information transaction in distributed computing systems.

  3. Fault detection and isolation - Wikipedia

    en.wikipedia.org/wiki/Fault_detection_and_isolation

    Fault detection, isolation, and recovery (FDIR) is a subfield of control engineering which concerns itself with monitoring a system, identifying when a fault has occurred, and pinpointing the type of fault and its location. Two approaches can be distinguished: A direct pattern recognition of sensor readings that indicate a fault and an analysis ...

  4. Time-domain reflectometer - Wikipedia

    en.wikipedia.org/wiki/Time-domain_reflectometer

    Time-domain reflectometer for cable fault detection. A time-domain reflectometer (TDR) is an electronic instrument used to determine the characteristics of electrical lines by observing reflected pulses.

  5. Receiver autonomous integrity monitoring - Wikipedia

    en.wikipedia.org/wiki/Receiver_Autonomous...

    In order for a GPS receiver to perform RAIM or fault detection (FD) function, a minimum of five visible satellites with satisfactory geometry must be visible to it. RAIM has various kinds of implementations; one of them performs consistency checks between all position solutions obtained with various subsets of the visible satellites.

  6. Watchdog timer - Wikipedia

    en.wikipedia.org/wiki/Watchdog_timer

    Watchdog timers are sometimes used to trigger the recording of system state information—which may be useful during fault recovery [4] —or debug information (which may be useful for determining the cause of the fault) onto a persistent medium. In such cases, a second timer—which is started when the first timer elapses—is typically used ...

  7. No fault found - Wikipedia

    en.wikipedia.org/wiki/No_fault_found

    No fault found (NFF), no trouble found (NTF) or no defect found (NDF) are terms used in the field of maintenance, where a unit is removed from service following a complaint of a perceived fault by operators or an alarm from its BIT (built-in test) equipment. The unit is then checked, but no anomaly is detected by the maintainer.

  8. Failure modes, effects, and diagnostic analysis - Wikipedia

    en.wikipedia.org/wiki/Failure_Modes,_Effects...

    The impact of any latent fault tests, and The operational profile (environmental stress factors). Given a component database calibrated with field failure data that is reasonably accurate, [ 1 ] the method can predict device level failure rate per failure mode, useful life, automatic diagnostic effectiveness, and latent fault test effectiveness ...

  9. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...