  2. ISO 13485 - Wikipedia

    en.wikipedia.org/wiki/ISO_13485

    ISO 13485 Medical devices -- Quality management systems -- Requirements for regulatory purposes is a voluntary standard, [1] published by International Organization for Standardization (ISO) for the first time in 1996, and contains a comprehensive quality management system for the design and manufacture of medical devices.

  3. Single use medical device reprocessing - Wikipedia

    en.wikipedia.org/wiki/Single_Use_Medical_Device...

    The practice of reusing medical devices labeled for only one use began in hospitals in the late 1970s. [8] After a thorough review by the U.S. FDA in 1999 and 2000, [8] the agency released a guidance document for reprocessed SUDs that began regulating the sale of these reprocessed devices on the market, [9] under the condition that third-party reprocessors would be treated as the manufacturer ...

  4. Design controls - Wikipedia

    en.wikipedia.org/wiki/Design_controls

    The Medical Devices Directive (MDD 93/42/EEC) similarly lists several requirements regarding the design of a medical device. The Medical Devices Regulation (MDR (EU) 2017/745), replacing the MDD from 2021, requires information to allow the design stages applied to the device to be understood as part of the design and manufacturing information ...

  5. Quality management system - Wikipedia

    en.wikipedia.org/wiki/Quality_management_system

    The two primary, state of the art, guidelines for medical device manufacturer QMS and related services today are the ISO 13485 standards and the US FDA 21 CFR 820 regulations. The two have a great deal of similarity, and many manufacturers adopt QMS that is compliant with both guidelines.

  6. Independent reviewer - Wikipedia

    en.wikipedia.org/wiki/Independent_reviewer

    The US Food and Drug Administration requires that developers of medical device follow a system of design controls.A key part of this system is design review, defined in 21CFR820.3 section (h) as "a documented, comprehensive, systematic examination of the design to evaluate the adequacy of the design requirements, to evaluate the capability of the design to meet these requirements, and to ...

  7. Device Master Record - Wikipedia

    en.wikipedia.org/wiki/Device_Master_Record

    The sub-clause 4.2.3 of ISO 13485:2016 requires a manufacturer of medical device to establish a Technical file, similar to a device master record. The EU medical device regulation requires a manufacturer of a medical device to maintain a Technical documentation.

  8. ISO 9000 family - Wikipedia

    en.wikipedia.org/wiki/ISO_9000_family

    ISO 13485:2016 is the medical industry's equivalent of ISO 9001. ISO 13485:2016 is a stand-alone standard. Because ISO 13485 is relevant to medical device manufacturers (unlike ISO 9001, which is applicable to any industry), and because of the differences between the two standards relating to continual improvement, compliance with ISO 13485 ...

  9. Design history file - Wikipedia

    en.wikipedia.org/wiki/Design_history_file

    A design history file is a compilation of documentation that describes the design history of a finished medical device.The design history file, or DHF, is part of regulation introduced in 1990 when the U.S. Congress passed the Safe Medical Devices Act, which established new standards for medical devices that can cause or contribute to the death, serious illness, or injury of a patient.