Search results
Results from the WOW.Com Content Network
A liquid (glycol based) chiller with an air cooled condenser on the rooftop of a medium size commercial building. In air conditioning systems, chilled coolant, usually chilled water mixed with ethylene glycol, from a chiller in an air conditioning or cooling plant is typically distributed to heat exchangers, or coils, in air handlers or other types of terminal devices which cool the air in ...
A water chiller [1] is a device used to lower the temperature of water. Most chillers use refrigerant in a closed loop system to facilitate heat exchange from water where the refrigerant is then pumped to a location where the waste heat is transferred to the atmosphere. However, there are other methods in performing this action.
The cooling towers of a large chilled water system. As part of a chilled water system, the condenser water absorbs heat from the refrigerant in the condenser barrel of the water chiller and is then sent via return lines to a cooling tower, which is a heat exchange device used to transfer waste heat to the atmosphere.
Water is inexpensive, non-toxic, and available over most of the earth's surface.Liquid cooling offers higher thermal conductivity than air cooling. Water has unusually high specific heat capacity among commonly available liquids at room temperature and atmospheric pressure allowing efficient heat transfer over distance with low rates of mass transfer.
A chiller is essentially a refrigerator that includes a compressor, evaporator, condenser and a metering device.An additional buffer tank is used with the chilling unit to provide additional system capacity to prevent excessive cycling, unexpected temperature fluctuations, and erratic system operation.
Free cooling is an economical method of using low external air temperatures to assist in chilling water, which can then be used for industrial processes, or air conditioning systems. The chilled water can either be used immediately or be stored for the short- or long-term.
A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.
This allows the water to get cold more quickly again at the expense of having a lower volume of cold water available. Ice-bank Cooling System - A pressurized stainless steel coil and a copper coil is immersed in a reservoir full of pre-chilled water. The copper coil containing the refrigerant gas freezes the water contained within the reservoir ...