IEC/TR 80002-1:2009 Part 1: Guidance on the application of ISO 14971 to medical device software; ISO/TR 80002-2:2017 Part 2: Validation of software for medical device quality systems; IEC/TR 80002-3:2014 Part 3: Process reference model of medical device software life cycle processes ; ISO/TS 80004 Nanotechnologies – Vocabulary
The capacity of an isolation amplifier is a function of two key isolation amplifier specifications: The amplifier’s isolation breakdown voltage, which defines the absolute maximum common mode voltage that it will tolerate without damage. Specifications of 1,000 volts and more are common. The amplifier’s common mode rejection ratio (CMRR ...
In electrical engineering, an electrical isolation test is a direct current (DC) or alternating current (AC) resistance test that is performed on sub-systems of an electronic system to verify that a specified level of isolation resistance is met. Isolation testing may also be conducted between one or more electrical circuits of the same ...
Galvanic isolation is used where two or more electric circuits must communicate, but their grounds may be at different potentials. It is an effective method of breaking ground loops by preventing unwanted current from flowing between two units sharing a ground conductor .
A reference designator unambiguously identifies the location of a component within an electrical schematic or on a printed circuit board.The reference designator usually consists of one or two letters followed by a number, e.g. C3, D1, R4, U15.
Figure 1: Example two-port network with symbol definitions. Notice the port condition is satisfied: the same current flows into each port as leaves that port.. In electronics, a two-port network (a kind of four-terminal network or quadripole) is an electrical network (i.e. a circuit) or device with two pairs of terminals to connect to external circuits.
In electrical circuit theory, a port is a pair of terminals connecting an electrical network or circuit to an external circuit, as a point of entry or exit for electrical energy. A port consists of two nodes (terminals) connected to an outside circuit which meets the port condition – the currents flowing into the two nodes must be equal and ...
A common form of in-circuit testing uses a bed-of-nails tester.This is a fixture that uses an array of spring-loaded pins known as "pogo pins". When a printed circuit board is aligned with and pressed down onto the bed-of-nails tester, the pins make electrical contact with locations on the circuit board, allowing them to be used as test points for in-circuit testing.