Million standard cubic feet per day is a unit of measurement for gases that is predominantly used in the United States.It is frequently abbreviated MMSCFD. MMSCFD is commonly used as a measure of natural gas, liquefied petroleum gas, compressed natural gas and other gases that are extracted, processed or transported in large quantities.
1 Nm 3 of any gas (measured at 0 °C and 1 atmosphere of absolute pressure) equals 37.326 scf of that gas (measured at 60 °F and 1 atmosphere of absolute pressure). 1 kmol of any ideal gas equals 22.414 Nm 3 of that gas at 0 °C and 1 atmosphere of absolute pressure ... and 1 lbmol of any ideal gas equals 379.482 scf of that gas at 60 °F and ...
The standard temperature for metric measurement is 15 degrees Celsius (i.e. 59 degrees Fahrenheit) while for English measurement the standard temperature is 60 °F. Gas undergoes a slight expansion when the temperature is raised from 15 °C (59 °F) to 60 °F and this expansion is built into the above factor for gas.
Metric prefixes; Text Symbol Factor or; yotta Y 10 24: 1 000 000 000 000 000 000 000 000: zetta Z 10 21: 1 000 000 000 000 000 000 000: exa E 10 18: 1 000 000 000 000 000 000: peta P 10 15: 1 000 000 000 000 000: tera T
Yet other definitions are in use for industrial gas, [5] where, in the US, a standard cubic foot for industrial gas use is defined at 70 °F (21.1 °C) and 14.696 psia (101.325 kPa), while in Canada, a standard cubic meter for industrial gas use is defined at 15 °C (59 °F) and 101.325 kPa (14.696 psia).
References will be made to "actual" flow rate through a meter and "standard" or "base" flow rate through a meter with units such as acm/h (actual cubic meters per hour), sm 3 /sec (standard cubic meters per second), kscm/h (thousand standard cubic meters per hour), LFM (linear feet per minute), or MMSCFD (million standard cubic feet per day).
Since 1982, STP has been defined as a temperature of 273.15 K (0 °C, 32 °F) and an absolute pressure of exactly 1 bar (100 kPa, 10 5 Pa). NIST uses a temperature of 20 °C (293.15 K, 68 °F) and an absolute pressure of 1 atm (14.696 psi, 101.325 kPa). [3] This standard is also called normal temperature and pressure (abbreviated as NTP).
For example, a mass flow rate of 1,000 kg/h of air at 1 atmosphere of absolute pressure is 455 SCFM when defined at 32 °F (0 °C) but 481 SCFM when defined at 60 °F (16 °C). Due to the variability of the definition and the consequences of ambiguity, it is best engineering practice to state what standard conditions are used when communicating ...