Humphrey field analyser (HFA) is a tool for measuring the human visual field that is commonly used by optometrists, orthoptists and ophthalmologists, particularly for detecting monocular visual field. [1] The results of the analyser identify the type of vision defect.
The Goldmann perimeter is a hollow white spherical bowl positioned a set distance in front of the patient. [3] An examiner presents a test light of variable size and intensity. The light may move towards the center from the perimeter (kinetic perimetry), or it may remain in one location (static perimetry).
It measures visual acuity loss: positive values indicate vision loss, while negative values denote normal or better visual acuity. This scale is commonly used clinically and in research because the lines are of equal length and so it forms a continuous scale with equally spaced intervals between points, unlike Snellen charts, which have ...
Confrontation visual field testing is an important part of a routine ophthalmological or neurological examination. It can be used for rapid and gross assessment of large-scale visual field problems due to ophthalmological or neurological diseases, such as homonymous and heteronymous hemianopias, quadranopsia, altitudinal visual loss, central/centrocecal scotoma etc. [1] [2] Test using a red ...
Snellen chart. The Snellen chart, which dates back to 1862, is also commonly used to estimate visual acuity.A Snellen score of 6/6 (20/20), indicating that an observer can resolve details as small as 1 minute of visual angle, corresponds to a LogMAR of 0 (since the base-10 logarithm of 1 is 0); a Snellen score of 6/12 (20/40), indicating an observer can resolve details as small as 2 minutes of ...
Visual hyperacuity is at least 10 times more sensitive than visual acuity, the ability to separate between distinct objects. [4] Therefore, in retinal diseases such as macular degeneration responses to hyperacuity stimuli may be abnormal long before any changes in visual acuity are observed.
The value D, indicated to the left of each row, gives the distance in meters from which a person with a visual acuity of 1.0 can read the corresponding row. The value V, indicated to the right, gives the minimum visual acuity needed to read the row from a distance of 5 meters. The first row contains symbols 70 mm in size (V = 0.1); the second ...
The minimum perceivable angle of the gap is taken as measure of the visual acuity. It is generally practised in the laboratory. [1] The stroke width is 1 ⁄ 5 of the diameter, and the gap width is the same. [2] This is identical to the letter C from a Snellen chart. The Landolt C is the standard optotype for acuity measurement in most European ...