enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Direct exchange geothermal heat pump - Wikipedia

    en.wikipedia.org/wiki/Direct_exchange_geothermal...

    A direct exchange (DX) geothermal heat pump is a type of ground source heat pump in which refrigerant circulates through copper tubing placed in the ground unlike other ground source heat pumps where refrigerant is restricted to the heat pump itself with a secondary loop in the ground filled with a mixture of water and anti-freeze. [1]

  3. Ground source heat pump - Wikipedia

    en.wikipedia.org/wiki/Ground_source_heat_pump

    A heat pump in combination with heat and cold storage. A ground source heat pump (also geothermal heat pump) is a heating/cooling system for buildings that use a type of heat pump to transfer heat to or from the ground, taking advantage of the relative constancy of temperatures of the earth through the seasons.

  4. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The heat pump itself can be improved by increasing the size of the internal heat exchangers, which in turn increases the efficiency (and the cost) relative to the power of the compressor, and also by reducing the system's internal temperature gap over the compressor. Obviously, this latter measure makes some heat pumps unsuitable to produce ...

  5. Heat pump and refrigeration cycle - Wikipedia

    en.wikipedia.org/wiki/Heat_pump_and...

    Thermodynamic heat pump cycles or refrigeration cycles are the conceptual and mathematical models for heat pump, air conditioning and refrigeration systems. [1] A heat pump is a mechanical system that transmits heat from one location (the "source") at a certain temperature to another location (the "sink" or "heat sink") at a higher temperature. [2]

  6. Condenser (heat transfer) - Wikipedia

    en.wikipedia.org/wiki/Condenser_(heat_transfer)

    A condenser is designed to transfer heat from a working fluid (e.g. water in a steam power plant) to a secondary fluid or the surrounding air. The condenser relies on the efficient heat transfer that occurs during phase changes, in this case during the condensation of a vapor into a liquid. The vapor typically enters the condenser at a ...

  7. Heating seasonal performance factor - Wikipedia

    en.wikipedia.org/wiki/Heating_seasonal...

    The HSPF is related to the non-dimensional Coefficient of Performance (COP) for a heat pump, which measures the ratio of heat delivered to work done by the compressor. The HSPF can be converted to a seasonally-averaged COP assuming a lossless compressor and no heat loss by multiplying by the heat/energy equivalence factor .29307111 watts per BTU.

  8. Heat pump - Wikipedia

    en.wikipedia.org/wiki/Heat_pump

    Specifically, the heat pump transfers thermal energy using a heat pump and refrigeration cycle, cooling the cool space and warming the warm space. [1] In winter a heat pump can move heat from the cool outdoors to warm a house; the pump may also be designed to move heat from the house to the warmer outdoors in summer.

  9. Surface condenser - Wikipedia

    en.wikipedia.org/wiki/Surface_condenser

    A surface condenser is a water-cooled shell and tube heat exchanger installed to condense exhaust steam from a steam turbine in thermal power stations. [1] [2] [3] These condensers are heat exchangers which convert steam from its gaseous to its liquid state at a pressure below atmospheric pressure. Where cooling water is in short supply, an air ...