  2. Fire damper - Wikipedia

    en.wikipedia.org/wiki/Fire_damper

    Fire dampers (or fire shutters) are passive fire protection products used in heating, ventilation, and air conditioning (HVAC) ducts to prevent and isolate the spread of fire inside the ductwork through fire-resistance rated walls and floors. [1] Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the ...

  3. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    Canada de-rates closures, where, for instance a 2-hour closure is acceptable for use in a 3-hour fire separation, so long as the fire separation is not an occupancy separation or firewall. The lowered rating is then referred to as a fire protection rating, both for firestops, unless they contain plastic pipes and regular closures. Firestops

  4. Smokeproof enclosure - Wikipedia

    en.wikipedia.org/wiki/Smokeproof_enclosure

    For fully sprinkled buildings, the required rating is just one hour.) [4] The fans must be connected to an emergency power supply, and capable of both automatic activation by various fire and smoke detectors, and of manual activation by a central command post or by the actuation of a general fire alarm.

  5. Smoke damper - Wikipedia

    en.wikipedia.org/wiki/Smoke_damper

    Smoke damper may be used to prevent the spread of smoke from the space of fire origin to other spaces in the same building. A combination of fans and dampers can exhaust smoke from an area while pressurizing the smoke-free areas around the affected area (inhibiting smoke infiltration into additional areas).

  6. Pressurisation ductwork - Wikipedia

    en.wikipedia.org/wiki/Pressurisation_ductwork

    There are two means of providing fire-resistance rated ductwork: Inherently fire-resistant, or proprietary factory assembled ducts which are made of sheet metal shells filled with mixtures of rockwool, fiber and silicon dioxide; Sheet metal duct with exterior fireproofing materials such as blanket rockwool, ceramic fiber, or intumescent paint.

  7. Fire door - Wikipedia

    en.wikipedia.org/wiki/Fire_door

    Fire-resistance rated door, with wire mesh glass vision panel Industrial grade fire door rated to hydrocarbon curve and blast resistance Double fire door immediately after 3-hour fire test inside a 4-hour rated Durasteel wall Double fire door after 3-hour fire test in a 4-hour Durasteel wall, during successful 45PSI (3.1 bar) hose stream test leading to a UL Listing [1]

  8. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Vertically mounted fire dampers are gravity operated, while horizontal fire dampers are spring powered. A fire damper's most important feature is a mechanical fusible link which is a piece of metal that will melt or break at a specified temperature. This allows the damper to close (either from gravity or spring power), effectively sealing the ...

  9. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    This rating is the requirement in data safes and vault structures for protecting digital information on magnetic media or hard drives. Temperatures inside the protected chamber must be held below 125 °F (52 °C) for the time period specified, such as Class 125-2 Hour, with temperatures up to 2,000 °F (1,090 °C) outside the vault.