(G) PVC Water Stops; 1 Code of practice for the provision of water stops. IS 12200 – 1987 2 Procedure for Testing Parts of IS 8543-19 3 Standard Test Methods for Tensile Properties of Plastics. ASTM : D 638-1991 4 Standard Test Methods for Thermoplastic Elastomers-Tension. ASTM : D 412-1992 (H) HYSD BARS; 1 Specifications for HYSD bars.
The supplying of water is done with a Mariotte's bottle. Falling head refers to condition where water is supplied in the ring, and the water is allowed to drop with time. The operator records how much water goes into the soil for a given time period. The rate of which water goes into the soil is related to the soil's hydraulic conductivity.
The Atterberg limits are a basic measure of the critical water contents of a fine-grained soil: its shrinkage limit, plastic limit, and liquid limit. Depending on its water content, soil may appear in one of four states: solid, semi-solid, plastic and liquid. In each state, the consistency and behavior of soil are different, and consequently so ...
A percolation test (colloquially called a perc test) is a test to determine the water absorption rate of soil (that is, its capacity for percolation) in preparation for the building of a septic drain field (leach field) or infiltration basin. [1] The results of a percolation test are required to design a septic system properly.
The standard penetration test (SPT) is an in-situ dynamic penetration test designed to provide information on the geotechnical engineering properties of soil. This test is the most frequently used subsurface exploration drilling test performed worldwide. The test procedure is described in ISO 22476-3, ASTM D1586 [1] and Australian Standards AS ...
The maximum rate at that water can enter soil in a given condition is the infiltration capacity. If the arrival of the water at the soil surface is less than the infiltration capacity, it is sometimes analyzed using hydrology transport models, mathematical models that consider infiltration, runoff, and channel flow to predict river flow rates ...
ASTM D1941 – 91(2013) Standard Test Method for Open Channel Flow Measurement of Water with the Parshall Flume; ISO 9826:1992 Measurement of Liquid Flow in Open Channels – Parshall and SANIIRI Flumes; JIS B7553-1993 Parshall Flume Type Flowmeters; Bos, Marinus (1989). Discharge Measurement Structures. Third edition revised. Publication 20 ...
This test is used by Caltrans for pavement design, replacing the California bearing ratio test. Soil compaction tests Standard Proctor (ASTM D698), Modified Proctor (ASTM D1557), and California Test 216. These tests are used to determine the maximum unit weight and optimal water content a soil can achieve for a given compaction effort.